Determine failure mode by observing flashing LED status on ignition module.

LED status and probable cause shown below.

* Denotes conditions that may require the water heater to be isolated from the vent

system to determine root cause.

LED status & probable cause

For models with Hot Surface Ignition

LED STATUS

Power & flame

light flashing.

Probable Cause

Supply voltage

polarity.

LED STATUS

Valve light flashing.

Probable Cause

Flame sensor.

(see “Flame Sensor

Testing and Replacement”)

Probable Cause

Hot surface igniter.

(see “Hot Surface

Igniter Testing and

Replacement”)

Probable Cause*

Combustion system.

(see “Combustion

System Testing and

Replacement”)

Probable Cause*

Intake pressure switch. Only for

models prior to CF serial number

(see “Intake Pressure Switch

Testing and Replacement”)

Probable Cause

Blower.

(see “Blower Testing

and Replacement”)

Probable Cause*

Exhaust pressure

switch. (see “Exhaust

Pressure Switch

Testing and

Replacement”)

LED STATUS

Purge light flashing.

LED STATUS

Only power light

is on and water heater

will not function.

Probable Cause

Thermostat circuit.

(see “Thermostat Circuit

Testing and Replacement”)

Probable Cause*

Exhaust pressure

switch. (see “Exhaust

Pressure Switch

Testing and

Replacement”)

Probable Cause

Vent safety switch.

(see “Vent Safety Switch

Testing and Replacement”)

17

17