Spark Rod Gap Inspection and Adjustment

Step 1.

Remove combustion system as described in

“Combustion System Removal Procedure”.

Step 2.

Measure spark gap between the spark rod

and burner tube. Acceptable spark gap is

between 3/16" - 1/4" (see photo below).

Step 3.

If spark gap is not between 3/16" - 1/4“, the

spark rod may be carefully bent by supporting

the end near the ceramic insulator with pliers

and bending the end near the burner tube

with needle nose pliers (see photo below).

Step 4.

Re-measure and verify spark gap is between 3/16" - 1/4“ after bending.

Step 5.

Reinstall the combustion system per “Combustion System Replacement Procedure” and check several

ignitions to ensure the burner lights smoothly.

Spark Rod

Burner Tube

Spark Rod

Hold spark rod

near ceramic

insulator

Bend spark

rod near

burner tube

CAUTION

Use caution while performing these

steps to prevent stressing or cracking

the ceramic insulator.

WARNING

Spark gap must be set to 3/16" to 1/4".

Failure to set and verify proper spark

gap may result in a delayed ignition

resulting in damage to the water heater.