Bradford White EF-100T-399-3X User Manual

Page 4

Advertising
background image

It is intended for this manual to be used by qualified service personal for the primary purpose

of troubleshooting analysis and repair of the Bradford White eF Series

®

Ultra High

Efficiency Water Heater. Understanding the sequence of operation section of this manual will

contribute greatly to troubleshooting this product.

An “Installation Check List” is shown towards the end of this manual. Compare the installation

against the installation check list to confirm all requirements are met.

An “eF Service Report” is shown towards the end of this manual. Completing this form will

assist in the troubleshooting efforts. Should you need to call for technical support, Please

provide the information shown on this form to the support technician to insure accurate

troubleshooting.

Troubleshooting begins with “System Observation” to determine failure mode as indicated by

the LED status of the ignition module. Troubleshooting continues with “Failure Modes and

Probable cause” directing the service provider to a series of test procedures to determine

root cause of failure. Component replacement procedures directly follow the test procedures

for a given component.

In some difficult to diagnose conditions, it may be necessary to isolate the heater from the

vent system to determine root cause.

Contact Technical support immediately if diagnosis is not determined using the methods

described in this service manual.

Manometer:

Two types available, a liquid “U” tube type or a digital (magna-helic)

type. This device is used to measure gas and/or air pressures and

vacuum.

Multi-Meter:

A digital type is strongly recommended. This device is used to measure

electrical values. The meter you select must have the capability to

measure volts AC, volts DC, Amps, micro-amps and ohms.

Thermometer:

Used to measure water temperature. An accurate thermometer is

recommended.

Water Pressure Gage:

Used to measure water supply pressure. Also used to determine tank

pressure by adapting to the drain valve of the heater.

Jumper Leads:

A length of wire (12" min.) with alligator clip at both ends.

Various Hand Tools:

Pipe wrench, channel locks, open end wrench set, 12" crescent wrench,

Allen wrench set, torx bit set, screw drivers (common & phillips), long

reach (12") magnetic tip phillips head screw driver #2 tip, ¼" nut driver,

pliers (common & needle nose), socket set including a 1-1/16 deep well

socket, wire cutters, wire strippers, wire crimpers, torpedo level, small

shop vac, step ladder, and flashlight.