Does inlet gas pressure

drop more than 2" W.C.

during burner ignition?

Adjust gas

supply regulator

Inadequately

sized regulator.

Y

N

N

Y

N

Y

N

Verify Minimum Gas Supply Piping Requirements of:

Minimum ¾" NPT. (Schedule 40 black Iron Pipe

recommended).

Reconfigure gas

supply piping

Y

Observe burner operation through the sight glass located on the combustion insert mounting flange. Normal burner

operation should ignite smoothly, without evidence of coughing or huffing upon ignition. The burner flame should be a blue

flame near the burner surface in a uniform flame pattern. Occasional yellow or white streaks are normal.

Inlet gas

pressure tap

Venturi

adjustment

Does main burner

Light?

Remove high voltage wire connected at the

spark rod and hold approximately ¼" from metal

ground with insulated pliers during the ignition

cycle (3 second spark trial period).

Is there spark to ground?

Y

N

Check spark gap to burner

(see “Spark Rod Gap

Inspection”)

Check resistance of high voltage

cable. Resistance should be 0-1 ohms.

If resistance is high, replace spark

cable. If spark cable is good, replace

Control Board.

N

Y

Can Sparking be seen/

heard at the spark rod

to the burner?

Proceed to next page

With manometer, check inlet

gas pressure. Is it stable

between 7" & 14" W.C. static?

(heater not running)

(see illustrations at right)

Is gas supply pressure

regulator adjustable to

maintain proper and

stable setting?

Y

N

WARNING

120 volt potential

exposure. Use caution

making voltage checks to

avoid personal injury.

WARNING

Removing screw from

inlet gas pressure tap will

immediately allow gas to

flow from pressure tap.

Note: On higher input models using metal fiber mesh burner a red

glow from the burner surface is normal.

45

Check continuity of

spark rod. Is

reading 0-1 Ohm?

Y

N

Replace Spark Rod

(see “Spark Rod

Gap Inspection and

Replacement”

CHECK SPARK ROD

RESISTANCE

Meter probe

Meter probe

Spark Rod

Volt meter set to

OHM setting

Spark Rod

Voltmeter set to

OHM setting

Serial Numbers including and AFTER GB13006174 and ALL EFR models