Bradford White EF-100T-399-3X User Manual

Page 30

Advertising
background image

Accessing Service Mode on Control Display

For models with Honeywell Integrated Control

Step 5: Pressing “Select” button will return display to setpoint in format selected (°F or °C) immediately

SELECT

SET

Status

°F

idle

Operational

Lower Sensor

Error Codes and Error History Display:
If there is an operating problem with the water heater, an error code number will appear on the water heater display with

“Service Needed” to the right of the “Status” indicator. The error code label is located under the Water Heater Display

and the following section in this Service Manual explains the error codes with corrective actions to repair the water

heater.

SELECT

SET

idle

Service Needed

Example of Error Code in the Display

Error Code History:
In “Service Mode” pressing the “Select” button after the “Software Version” (item 8 in the previously described sequence

of service modes) will show an error code history, if there have been any previous operating problems with the water

heater. If the display shows --, there is not a current error code.

The Water Heater Display will provide up to 10 previous error codes. The oldest error code will be stored in code index

#1 and the most recent in code index #10.