Safety circuit trace, Warning – Bradford White EF-100T-399-3X User Manual

Page 54

Advertising
background image

Does blower

energize?

N

Y

Sequence of operation:

With the thermostat calling for heat, prior to energizing blower, the ignition module checks the exhaust pressure switch for normal

switch position of normally open. If the exhaust pressure switch contacts are closed (not in normal position), the ignition module

waits 45 seconds for the pressure switch contacts to open. If the pressure switch contacts do not open after 45 seconds, the

ignition module locks out with the PURGE LED flashing indicating a pressure switch fault.

Is there continuity

Through GREY

wire leads of heater side

safety circuit harness?

(see photo below)

N

Y

Is there continuity

through RED

wire leads of heater side

safety circuit harness?

(see photo below)

N

Check PURGE LED status.

Y

Safety Circuit OK,

(see “Blower Testing

& Replacement”)

Replace exhaust

pressure switch (see

“Exhaust Pressure

Switch Replacement

Procedure”)

Replace vent safety

switch.

(see “Vent Safety

Switch Replacement

Procedure”)

Call technical

support.

Y

N

Depress reset

button on vent

safety switch. Is

there continuity

across high limit

switch?

(see photo below)

Refer to

“Check Collector Pressure”

(see next page)

Check blower for proper

operation (see page 27)

Is blower OK?

N

Check PURGE LED status

on ignition module,

Flashing after 45 seconds?

On within 5 minutes?

Pressure switch is OK.

Y

Y

Safety Circuit Trace

Does heater

function?

Verify proper

switch operation.

(see “Vent Safety

Switch Testing and

Replacement”)

N

Y

LED Status

Only power LED is on, or

Purge LED flashing.

Exhaust Pressure Switch Testing and Replacement

For serial numbers prior to “CF”

N

Flashing after

5 minutes?

Call for technical

support.

Correct blower problem

(see “Blower Testing and

Replacement”)

N

Y

Y

WARNING

120 volt potential exposure. Use caution

making voltage checks to avoid personal injury.

Heater side

harness

Control side

harness

Reset button

54

54

Advertising
This manual is related to the following products: