Application examples
This example is based on a light curtain with a height = 600 mm.
To calculate the distance of the device from the light curtain in a vertical position, the
following formula is applied:

S = K*T + C

Therefore:
T = t

1

+ t

2

t

1

= Response time of light curtain + release time of relay (specific time of PNOZ S3: 20ms)

With a reaction time of the light curtain of 15 ms the result is a max. of 35 ms for t

1

t

2

= Machine’s overall stopping performance in seconds

C = 8 * (d – 14) for devices with resolution <= 40 mm
D = Resolution

In each case, if K = 2000 mm/sec, then S > 500 mm. The safety distance will then need to be
recalculated, based on K = 1600 mm/sec.

WARNING: In this case the reference standard is EN ISO 13855
“Safety of machinery – Positioning of protective equipment in
respect of approach speeds of parts of the human body”.

The information provided here should be regarded as a summary
and is non-binding. Please refer to the complete standard ISO
13855 for details of how to calculate safety distances correctly.