PSENopt Advanced RX Blanking

18

pin

M12 12 pin

M12 12-Pin:

1.

24 V (brown)

2.

0 V (blue)

3.

RESET/RESTART/ALIGN (white)

4.

TEACH IN (green)

5.

OSSD2 (pink)

6.

EDM (yellow)

7.

NC (black)

8.

OSSD1 (grey)

9.

TOLERANCE (red)

10.

LAMP (purple)

11.

NC (grey-pink)

12.

EARTHING (red-blue)

PSENopt Advanced TX

18

pin

M12 5 pin

M12 5-Pin:

1.

24 V (brown)

2.

TEST (white)

3.

0 V (blue)

4.

EARTH (black)

5.

REDUCED RANGE (grey)

Assignment of M12 connector

12-pin

5-pin


PSENopt Advanced RX Muting

CONNECTION

LINE

BEHAVIOUR

RESET

24Vdc

IN line

N.O.

Is connected – when in disabled state the
RESET/RESTART/ALIGN button is operated

RESTART

24Vdc

IN line

N.O.

Is connected – when during operation the
RESET/RESTART/ALIGN button is operated

ALIGNMENT

24Vdc

IN line

N.O.

Has to be set to 24 V DC at startup

OVERRIDE 1

24Vdc

IN line

N.O.

Is connected – when Override is active during
operation

OVERRIDE 2

IN line

N.O.

No voltage – during operation

EDM

See section 7.4 for
connections

Must be non-equivalent to OSSD during operation
with EDM enabled

MUTING
DEACTIVATION

24Vdc

IN line

N.O.

Muting is disabled when connecting