PSENopt Advanced RX Muting

CONNECTION

LINE

BEHAVIOUR

OSSD1 / OSSD 2

0V

OSSDs

Protected field clear
No voltage = Protected field not clear

OVERRIDE
STATUS

0V

OSSDs

High level = Override function active
Low level = Override function inactive

NOTE: This line signals the state of the override
signal inputs

MUTING LAMP

24Vdc

LAMP

The open collector connection is activated when
muting is activated.

MUTING1/MUTING2

24Vdc

IN line

N.O.

Is connected – when muting is active during
operation

FUNCTION EARTH

Connect to earth

PSENopt Advanced RX Blanking

CONNECTION

LINE

BEHAVIOUR

RESET

24Vdc

IN line

N.O.

Is connected – when in disabled state the
RESET/RESTART/ALIGN button is operated

RESTART

24Vdc

IN line

N.O.

Is connected – when during operation the
RESET/RESTART/ALIGN button is operated

ALIGNMENT

24Vdc

IN line

N.O.

Has to be set to 24 V DC at startup

TEACH-IN

24Vdc

IN line

N.O.

Is connected – when TEACH-IN button is operated
during operation

TOLERANCE

24Vdc

IN line

N.O.

Has to be set to 24 V DC at startup

EDM

See Chapter 7.4 for
connections

Must be non-equivalent to OSSD during operation
with EDM enabled

OSSD1 / OSSD 2

0V

OSSDs

Protected field clear
No voltage = Protected field not clear

BLANKING LAMP

24Vdc

LAMP

The open collector connection is switched when
blanking is activated.

FUNCTION
EARTH

Connect to earth

PSENopt Advanced TX

CONNECTION

LINE

BEHAVIOUR

TEST

24Vdc

IN line

N.O.

is connected, when the RESET button is
operated during operation

REDUCED RANGE

24Vdc

IN line

N.O.


Has to be set to 24 V DC at startup

FUNCTION EARTH

Connect to earth