Pilz PSEN op4F-A-14-180/1 User Manual

Page 24

Advertising
background image

PSEN op4F/H-A series

OPERATING MANUAL

24

1003067-EN-02

The mounting positions recommended based on the length of the light curtain are stated in
Fig. 19 and in the following table.

Fig. 19 – Light curtain dimensions

MODEL

L (mm)

L (mm)

incl. PSEN op

advanced

programming

adapter

A (mm)

B (mm) C (mm)

PSEN op4F-A-14-030/1
PSEN op4H-A-30-030/1

306.3

363.2

86.3

110

-

PSEN op4F-A-14-045/1
PSEN op4H-A-30-045/1

456.3

513.2

236.3

110

-

PSEN op4F-A-14-060/1
PSEN op4H-A-30-060/1

606.2

663.1

306.2

150

-

PSEN op4F-A-14-075/1
PSEN op4H-A-30-075/1

756.2

813.1

406.2

175

-

PSEN op4F-A-14-090/1
PSEN op4H-A-30-090/1

906.1

963.0

506.1

200

-

PSEN op4F-A-14-105/1
PSEN op4H-A-30-105/1

1056.1

1113.0

606.1

225

-

PSEN op4F-A-14-120/1
PSEN op4H-A-30-120/1

1206

1262.9

966

150

453

PSEN op4F-A-14-135/1
PSEN op4H-A-30-135/1

1356

1412.9

1066

175

503

PSEN op4F-A-14-150/1
PSEN op4H-A-30-150/1

1505.9

1562.8

1166

200

553

PSEN op4F-A-14-165/1
PSEN op4H-A-30-165/1

1655.9

1712.8

1266

225

603

PSEN op4F-A-14-180/1
PSEN op4H-A-30-180/1

1805.8

1862.7

1366

250

652.9

Advertising