List of RX functions in blanking mode

(LED 3 OFF)

Function

LED

No.

Setting

LED status

P

W

R

O

S

S

D

E

DM

A

CM

LEVEL

Coding

2

Code 1

Code 2

No code

Selection of
muting/blanking

3

Muting

Blanking

EDM

4

Activated

Deactivated

Restart mode

5

Auto

Manual

Selection of
floating blanking

6-7

Floating blanking
deactivated

Floating blanking 1 beam

Floating blanking 2 beams

Reduced resolution 4 beams

Selection of fixed
blanking

8

1 fixed blanking zone

2 fixed blanking zones

List of TX functions

Function

LED

No.

Setting

LED status

P

W

R

TS

T

S

R

LR

CODE

Coding

2

Code 1

Code 2

No code

Selection of
operating range

3

Normal

Reduced