Care & maintenance trouble- shooting guide – Wilbur Curtis TL-ILGD User Manual

Page 4

Advertising
background image

4

REGUlAR AND PREVENTIVE MAINTENANCE IS ESSENTIAl IN

KEEPING yOUR GRINDER lOOKING AND wORKING lIKE NEw.

– ClEANING

1. The stainless steel outside case of the grinder may be cleaned with stainless steel polish.
2. Clean the hopper with a damp cloth.

3. you can clean inside the grinder housing with a stiff bristled brush to get out all of the old coffee

grounds. Refer to section on adjusting the grinds to open the housing. While cleaning the grinder, do not

wet inside the grinder housing.

CARE &

MAINTENANCE

TROUblE-

ShOOTING

GUIDE

SyMPTOM: MOTOR DOES NOT RUN

SyMPTOM: MOTOR RUNS bUT NO COFFEE COMES OUT

POSSIblE CAUSE

SOlUTION

4. Shear disk may have broken.

Change the shear disk (see page 6 for directions).

5. Funnel to grind housing may

Cut off power to machine. Empty the hopper of beans.

be jammed.

Clean where the hopper funnels into the grind housing.

POSSIblE CAUSE

SOlUTION

1. Circuit breaker may be tripped.

Grinder has a circuit breaker behind machine. Push in reset

button. you should hear a “click”.

2. Electrical cord may not be

Push plug into outlet.

making contact.

3. Electrical outlet may not

with voltmeter, determine if there is power at outlet.

have power.

SyMPTOM: GROUND COFFEE TEXTURE IS TOO COARSE

OR OF POOR QUAlITy

POSSIblE CAUSE

SOlUTION

6. grinding burrs may be worn.

Readjust the grind (see page 6).

7. housing cover may not be on

Pull off the cover and clean the mounting surfaces.

straight or not seating correctly.

Reassemble the housing.

cauTIon: do

not use any

substance con-

taining chlorine.

These products

will promote cor-

rosion.

This appliance is designed for commercial use. any servicing other than cleaning and

maintenance should be performed by an authorized Wilbur curtis service center.