ISH

INSTALLATION

Commissioning

Connection to terminal block X0

 Remove the appliance cover (See 14.1, “Removing the appli-

ance cover”, pg. 23).

D00000

34

8

03

1

1

Terminal X0

 Prepare the leads for connection to X0 in such a manner that

each lead terminating at X0 has a wire ferrule.

 Route leads through the strain relief.

 Connect the leads to X0 (see chapter "See 10.3.1, “Connection

with external signal transmitter”, pg. 20).

10.4 Assembling the appliance

Note
Refi t the appliance cover after completing your work.
See chapter "See 14.10, “Fitting the appliance cover”,
pg. 25).

11.

Commissioning

11.1

Commissioning

!

Material losses
Never connect the appliance to the power supply before
the DHW tank is fi lled.

Note
At temperatures below 5°F/-15°C, the high limit safety
cut-out may respond. The appliance may be subjected to
these temperatures during storage or transport.

 If required, press the high limit safety cut-out reset

button. See 13.3, “Resetting the high limit safety
cut-out”, pg. 22

Note
After an interruption of the power supply, compressor op-
eration remains blocked for at least one minute to allow
the electronic main board to initialize.
If the compressor subsequently fails to start, it may be
disrupted by additional safety devices (Klixon and high
pressure switch). This interruption due to the compressor
motor klixon is terminated automatically.
If the high pressure switch responds, it can be manually
reset after the pressure is less than 246 PSI. This normally
occurs 5 minutes after responding.

11.1.1 Filling the DHW tank

Fill the DHW tank and vent the pipework by following the proce-
dure below:

 Close the drain valve.

 Open all DHW tap points and the shut-off valve in the cold

water supply.

 Close the DHW tap points as soon as water starts to emerge

from them.

11.1.2 Settings / function check

 To check the function, select the maximum set temperature.

A higher set temperature allows for more mixed water but lower
effi ciency. A lower set temperature is more effi cient but less
mixed water is available. Never reduce the set temperature below
1 22°F/50°C to reduce problems with legionella.

11.1.3 Appliance handover

 Explain the appliance function to users and familiarize them

with its operation.

 Make users aware of potential dangers, especially the risk of

scalding.

 Make users aware of critical environmental factors and re-

quirements concerning the installation location.

 Inform users that water may drip from the safety valve

during the heating operation.

 Hand over these operating and installation instructions to

users for safe-keeping.

11.2

Recommissioning

If the appliance is switched off due to an interruption to the power
supply, no specifi c measures for restarting are required once the
power supply has been restored. The appliance has saved the
parameters most recently set and continues operating with these.

If the comfort heating function was active before interruption of
the power supply, this is reactivated with a set temperature of
149°F/65°C once the power supply has been established again.

Remote function is not reactivated after an interruption of the
power supply.