OPERATION

Safety

8

| Accelera® 220-300 E www.stiebel-eltron-usa.com

!

CAUTION
Hydrogen gas is produced by this heater in a hot water
system that has not been used for a long period of time
(2 weeks or more). Hydrogen gas is extremely fl amma-
ble. To reduce the risk of injury under these conditions,
it is recommended that the hot water faucet be opened
for several minutes at the kitchen sink before using any
electrical appliance connected to the hot water system.
When hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as
the water begins to fl ow. There should be no smoking or
open fl ame near the faucet at the time it is open.

!

Material losses
If you disconnect the appliance from the power supply, it
is no longer protected against frost.

 Do not interrupt the power supply to the appliance.

!

Material losses
Never cover this appliance. Covering the air intake or air
discharge leads to a reduced air supply. If the air supply
is restricted, the operational reliability of the appliance
cannot be guaranteed.

!

Material losses
Only operate the appliance when the DHW tank has been
fi lled.

!

Material losses
Keep the appliance installation room free from air con-
taminated with oil or salt and corrosive or explosive sub-
stances.

2.4

ETL

designation

The ETL designation shows that the appliance meets all essential
UL and CAN/CSA requirements. This appliance conforms to:

- UL Standard 1995

- UL Standard 174

- CAN/CSA Standard C22.2 No.236-05

- CAN/CSA Standard C22.2 No.110-94

2.5 Appliance

labels

1. Type plate label for the Accelera 220 E

Accelera 220 E

Stiebel Eltron Inc.
17 West Street
West Hatfield, MA 01088, USA
800.582.8423
[email protected]

Conforms to UL STD. 1995

Conforms to UL STD. 174

Certified to CAN/CSA STD. C22.2 No.236-05
Certified to CAN/CSA STD. C22.2 No.110-94

Part number/code article:

233058

Electrical/électrique
Voltage/tension:

Single phase 220-240 V

Frequency/fréquence:

50 / 60 Hz

Breaker/disjoncteur:

15 A

P

nmax

(rated power input)/puissance nominale:

2200 W

Maximum allowable ratings/courant nominal:

2200 W, 9.17 A

Protection class/indicie de protection:

IP 24

Heat pump/pompe à chaleur:
P

N

(Air 107.6°F / Water 149°F):

0.54 kW

Refrigerant/frigorigène:

R-134a

Refrigerant charge/frigorigène poids de remplissage:

1.874 lb / 850g

Max. operating pressure/max. pression de service:

348.1 PSI / 2,400 kPa

Lock rotor current/puissance blockade:

15.3 A

MCA:

14 A

Rated compressor load/courant nominale du compresseur:

2.5 A

Motor fan/moteur de ventilateur:

24 W

DHW cylinder/DHW cylindre:
Backup heating element/chauffage d'appoint:

1690 W

Max. operating pressure/max. pression de service:

87 PSI / 600 kPa

Max. operating temperature/max. temperature de service:

168.8°F / 76°C

Tank material/matériau réservoir:

Steel

Nominal capacity/capacité nominale:

58.12 gal / 220 l

Tank test pressure/contrôle de réservoir:

130.5 pSI / 900 kPa

No.:#### / ######

Made in EU/Fabriqué en UE

Read the instructions carefully.
Tested for leaks.
Lira attentivement la notice.
Étanchéité testé.

285872-34892

XX

XX

XX

-

XX

XX

-

XX

XX

XX

2. Condensate drain information label

315683-38055

Condensate

Condenso

31

1801-38055

Condensat

3. Hot water outlet location label

Hot Water Outlet

311803-38055

Salida de agua caliente

Sortie eau chaude

4. Cold water outlet location label

Cold Water Inlet

311802-38055

Entrada para agua fría

Entrée eau froide

5. Power connection information label

Power supply

Disconect power supply

Before opening the cover

!Attention!

Must connect to

240 V, 15 A

Double-pole

Circuit breaker