Access to components, Gigabit ethernet indicators, Opening the front panel – 360 Systems MAXX2400HD User Manual

Page 116: Removing the top cover

Advertising
background image

MAXX-2400HD Owner’s Manual

Page 115

Gigabit Ethernet Indicators


The Gigabit Network Port card has the following indicator lights:

Label

Indication

Meaning

Green on

The port is connected to a valid link partner

Green flashing

Data activity

ACT/LNK

(Left)

Off No

link

Off 10

Mb/sec

Green 100

Mb/sec

10=OFF

100=GREEN

1000=YELLOW

(Right)

Yellow 1000

Mb/sec

Access To Components

Be certain to shut down the server and disconnect the power cord before
opening the unit for service.


The following sections provide instruction on disassembly and re-assembly for maintenance.

Opening the Front Panel

The front panel is easily opened for access to the twelve disk drives, or for removing the server

from an equipment rack. Using a coin or a flat-blade screwdriver, unscrew the two large panel
fasteners on the left and right sides of the face panel. Pull outward and down to remove cover.

To re-install the front panel, verify that all wires are within the chassis, then place the front

panel into position and tighten the front panel access screws just enough to be snug.

Removing the Top Cover

Remove 3 Phillips screws from the rear edge and 2 from the middle of the top panel, slide the

cover toward the rear of the chassis, then lift.

(On older model servers, there may be latch buttons on the top panel. Press down on the two

latch buttons simultaneously, slide the cover toward the rear of the chassis, then lift.)