System Timing

The MAXX-2400HD is equipped for use with an external genlock signal as a timing reference.

This causes all outputs to be synchronous with other video signals in a facility.

Adjustment of Genlock Lines will fine tune this synchronization to compensate for differences

in equipment and wiring. This global setting for all outputs allows timing to be varied by one line
of video. This rarely if ever needs to be adjusted. If required, it would be adjusted so that the
output of the first line of video happens concurrently with other contributing inputs. The visible
effect is that the picture will rise or fall by one line when viewed at the output of a video switcher,
or on a genlocked monitor. Note that this setting can cause VANC data to appear on different and
possibly inappropriate lines.