360 Systems MAXX-2400SD User Manual

Page 126

Advertising
background image

____________________________________________________________________________________

Page 126

MAXX 2400 Owners Manual


Calibration Procedure

1. Position the jumper block J5 and J6 for Channel 1 output to obtain an analog output.

2. Play the test clip titled zTONE present on the Image Server disk. This stereo clip is

recorded at a level equivalent to a +4 dBu output level.

3. While observing the output level of audio Channel 1 Left on a calibrated meter, adjust

trimmer R71 until a level of exactly +4.00 dBu is obtained.

4. Repeat this procedure for audio Channel 1 Right, while adjusting trimmer R86, and also for

each subsequent audio channel using its associated trim pot.

Having established accurate gain settings for all analog audio outputs in steps 1 through 3 above,
calibrate the Image Server’s input gain as follows:

5. Using the graphic user interface, place server Channel 1 in the E-E mode, so that an input

signal will appear at its output.

6. While observing the output level of audio Channel 1-L, apply a 1 kHz sine wave from the

audio generator to audio Input 1-L.*

7. Adjust input trimmer R10 until a level of exactly +4.00 dBu is obtained at the output of

Channel 1L.

8. Repeat this procedure for audio Input 1-R, making the gain adjustment with input trimmer

R25.

The preceding steps establish a gain of unity through the server.

* In the absence of a generator, use the calibrated outputs of Channel 2 playing zTONE to

feed the inputs.

Advertising