360 Systems MAXX-2400SD User Manual

Page 71

Advertising
background image

____________________________________________________________________________________

MAXX 2400 Owners Manual

Page 71


The Image Server supports Group 1 embedded audio, which includes audio channels 1-4, 20-bit,
48 kHz, synchronous audio, as per SMPTE 272A.
The analog audio channels always input to and output from channels 1 and 2. Audio channels
1,2,3 & 4 always correspond to their like-numbered Group 1 Embedded Audio channels.

Note: When recording SDI, the SDI signal must be synchronous with genlock.


Using Audio Sample Rate Conversion
Two check-boxes are provided to engage built-in sample rate converters for either (or both) of
audio channel pairs 1 & 2, and 3 & 4. When checked, the incoming AES/EBU audio tracks are
converted to a 48K broadcast standard synchronized by video genlock.

The sample rate converters should be used in any of these cases:

1. The incoming digital audio and video are not referenced to the genlock.

2. The sync reference is set to INTERNAL.

3. The incoming digital audio is not at 48 KHz sample rate.


Note: Audio sample rate conversion is not applicable for Embedded Audio and Audio Rate
Conversion boxes will be grayed-out if the SDI/ Embedded audio check-box is selected, or if the
XLR audio inputs are jumpered for analog audio.

Advertising