Lan and power cables – Cisco IAD2430 User Manual

Page 55

Advertising
background image

3-19

Cisco IAD2430 Series Integrated Access Devices Hardware Installation Guide

OL-4234-06

Chapter 3 Installing Cisco IAD2430 Series IADs

Connecting Cables

to, or not shielded from, the off-premise wiring or power cables during a lightning strike or power
surge, the on-premise wiring can carry a dangerous discharge to the attached interface, equipment,
and nearby personnel.
Statement 338

Table 3-2

shows the results of the NEBS Type 1/3 power line cross tests performed on the

Cisco IAD2430 series FXS ports.

Note

The installation must comply with all applicable codes.

LAN and Power Cables

The LAN and power cables and connections are described in

Table 3-3

and shown in

Figure 3-17

and

Figure 3-18

.

Table 3-2

Results of the NEBS Power Line Cross Tests on FXS Ports

NEBS Tests

Results

50 V/0.33 A; 15 minutes

Passed

100 V/0.17 A; 15 minutes

Passed

200 V/1.00 A; 1–second pulses, 60 repetitions

Passed

Table 3-3

LAN, Administrative Access, and Power Cable Selection

Port or Connection

Color or Type Connected To

Cable

Fast Ethernet

Yellow

Fast Ethernet switch

Straight-through Fast Ethernet cable (not included)

Console

Light blue

PC or ASCII terminal
communication (COM) port

RJ-45-to-DB-9 console cable (included)

Auxiliary

Black

Modem for remote access

RJ-45-to-DB-25 auxiliary cable (included)

Power (not shown)

Power

100–240 VAC, 50–60 Hz

Grounding power cord (included)

1

1.

Power cables vary to meet local requirements.

Advertising