3-28

Cisco IAD2430 Series Integrated Access Devices Hardware Installation Guide

OL-4234-06

Chapter 3 Installing Cisco IAD2430 Series IADs

Connecting Cables

X.21

DTE only with EIA/TIA -530 signaling

Note

DTE ports require external clocking provided by a DCE device such as a CSU/DSU.

Cable

The type of cable you connect to the serial port automatically sets the port for DTE or DCE operation
and establishes the signaling standard.

Procedure

Use the procedure in this section to connect external equipment to the Cisco 2430 series IAD.

Step 1

Connect the appropriate serial interface cable between the WAN serial port and the serial port connector
(see

Figure 3-26

).

Figure 3-26

Serial Port Connection

Step 2

Connect the external equipment (CSU/DSU or other serial device).

Connecting a T1/E1-WAN Port to the Network Demarcation Device

To connect the T1/E1 port to a network demarcation device, use the procedure in this section.

Warning

To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network
voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some
LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables.
Statement 1021

88966

WIC

2T

CONN

SERIAL1

SERIAL2

CONN

Serial transition cable

Cisco 12-in-1

CSU/DSU

Connector for: EIA/TIA-232
EIA/TIA-449
V.35
X.21
EIA-530

(shown)