Cisco IAD2430 Series Integrated Access Devices Hardware Installation Guide

OL-4234-06

Chapter 3 Installing Cisco IAD2430 Series IADs

Connecting Backup Power

Connecting Backup Power

Cisco IAD2430 series IADs can be installed with optional backup power. Backup power to a
DC-powered IAD is provided by a battery backup system; see the

“Connecting a Backup Battery to a

DC-Powered IAD” section on page 3-33

section for connection instructions. Backup power to an

AC-powered IAD is provided by an uninterruptible power supply (UPS); see the

“Connecting an

Uninteruptible Power Supply UPS to an AC-Powered Cisco IAD2430 Series IAD” section on page 3-34

for connection instructions.

Note

UPS functionality is not available on the IAD2435 IAD.

Caution

The Cisco IAD2430 series IAD chassis provides inputs for both AC and DC power. Design your
installation to use only one type of power. Do not use AC and DC power at the same time. If you do, the
unit stops operating, and you must reboot it with only a single power source.

See

Table 3-6

for the maximum power requirements for each Cisco IAD2430 IAD model.

Connecting a Backup Battery to a DC-Powered IAD

Connect a 12-volt backup battery to the DC input connector on your Cisco IAD2430 series router.
Before you install a backup battery, be sure to read the installation instructions for the backup battery
equipment.

Figure 3-30

shows a setup using an external backup battery.

Note

Figure 3-30

shows one possible setup; please review your backup battery documentation before you set

up your system.

Table 3-6

Maximum Power Requirements

Cisco IAD2430 Model

Power Consumption (Watts)

IAD2431-8FX

50

IAD2431-16FXS

60

IAD2432-24FXS

70

IAD2431-1T1E1(no FXS analog
ports)

35

IAD2430-24FXS (no TI/E1or
WIC slot)

60

IAD2435-8FXS (no WIC slot)

60