Led status indicators, Fig. 73: connector/dip switches/leds, Led 1 - link (activity) – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 39: Led 2 - module status, Led 1 - link (activity) led 2 - module status, Age/selecting view ethernet/ip, Onnector/dip switches/leds

Advertising
background image

25

Cabling
Installation

FIG. 70: CONFIGURATION PAGE/SELECTING

OPTIONS

FIG. 71: OPTIONS PAGE/SELECTING VIEW ETH-

ERNET/IP CONFIGURATION

Step 4. Click on View EtherNet/IP configuration. (See Fig.

113) The EtherNet/IP page appears. (See Fig. 72)

FIG. 72: ETHERNET/IP PAGE/SETTING IP

ADDRESS

Step 5. Click in the IP Address text field. Delete the current

IP Address.

Step 6. Type in the new IP address.
Step 7. If necessary repeat steps 6 & 7 for the Network

Mask and Gateway.

Step 8. Click on the Set Parameters button to save the

parameters.

Step 9. Click on the left arrow or the word “home” at the

bottom of the page to return to the Home Page.

LED Status Indicators

FIG. 73: CONNECTOR/DIP SWITCHES/LEDS

The Ethernet/IP Card is fitted with four bi-color status and
indicator LED’s. (See Fig. 115) During startup the Module
Status (LED 2) and Network Status (LED 3) are red for one
(1) second to indicate they are working properly. After the
one second period they are lit as specified below in the
tables. The HI 3000 Series products use the default settings.

LED 1 - Link (Activity)

LED 1 Configuration

LED 2 - Module Status

LED 2 Configuration

Color

State

Indicates:

Green

Steady On

Module has a link

Green

Steady Off

Module does not sense a link

TABLE 9: LED 1 - MODULE STATUS/CONFIGURATION

State

Summary

Description

Steady Off

No Power

No power applied to the module

Steady Green

Device
Operational

The module is operating properly

Flashing
Green

Standby

The module has not been configured

Flashing Red

Minor Fault

A minor recoverable fault has been
detected

TABLE 10: LED 2 CONFIGURATION

1 2 3 4 5 6 7 8
ON

RJ 45
Connector

Dip
Switches

LED 1

LED 2

LED 4

LED 3