Network
Installation

Devicenet Network Setup

RSNetWorx Setup for HI 3000 Series Instruments

Step 1. Download the Hardy EDS file either from the CD

that came with your instrument or go to the Hardy
Instruments Website to get the most current file. Put
the Hardy EDS file in the Rockwell Software
folder. DO NOT PUT THE EDS FILE IN THE
EDS FOLDER!

Step 2. Start up RSNetWorx.
Step 3. Click on the Tools pull down menu. (See Fig. 110)
Step 4. Click on EDS Wizard. The EDS Wizard dialog box

appears. (See Fig. 111)

FIG. 110: SELECTING EDS WIZARD

Step 5. Click on Next. The EDS Options dialog box

appears. (See Fig. 112)

FIG. 111: EDS WIZARD DIALOG BOX

FIG. 112: SELECTING “REGISTER AN EDS FILE”

Step 6. Click on Next. (See Fig. 112) The Registration dia-

log box appears.

Step 7. Click on the Browse button. The Select EDS file

dialog box appears. Go to the folder that contains
the Hardy EDS file. We put the file in the Rockwell
Software folder. (See Fig. 113)

Step 8. Click on the Hardy EDS file to highlight it.
Step 9. Click on Open. (See Fig. 113)
Step 10. The Registration dialog box reappears with the path

to the Hardy EDS file in the text field. (See Fig.
114)

FIG. 113: SELECTING THE HARDY EDS FILE