HI-3000 Series

84

Operation and Installation

Step 3. Click on New Module. The Select Module type dia-

log box appears. (See Fig. 342)

FIG. 292: SELECT MODULE TYPE

Step 4. Scroll down until you find “ETHERNET-MOD-

ULE Generic Ethernet Module”

Step 5. Click on the Generic Ethernet Module.
Step 6. Click on the OK button to select the module type.

The Module Properties - EtherNet_Bridge
(ETHERNET-MODULE 1.1) dialog box appears.
(See Fig. 293)

FIG. 293: MODULE PROPERTIES DIALOG BOX

Step 7. In the text field next to Name type in the name you

want to use for the module. In our example we used
Hardy.

Step 8. In the Description text field type in a description of

the module. In our example we entered 3010 Unit.

Step 9. Click on the Comm Format pull down menu.
Step 10. Click on “Data-INT”.
Step 11. Click in the IP address field.
Step 12. Enter the IP address of the module you are config-

uring.

Step 13. Under “Connection Parameters” enter the follow-

ing:

Step 14. Click on the Next button.
Step 15. In the Requested Packet Interval (RPI) field use the

up or down arrows to select 50 milliseconds, or
double click in the field and type 50.0. (See Fig.
294)

Step 16. Make sure that the Inhibit Module is not checked.

FIG. 294: REQUESTED PACKED INTERVAL/

SELECTING 50.0 MILLISECONDS

Step 17. Click on the Next button or the Finish button. The

original dialog appears with the newly added
“ETHERNET-MODULEHARDY” added to the I/
O configuration list and the Controller Tags list.
(See Fig. 295)

FIG. 295: ETHERNET-MODULE HARDY ADDED TO

I/O CONFIGURATION LIST

Assembly

Instance

Size

100

125

150

125

1

0