LED Indicators

FIG. 77: LED INDICATORS

1.

LED #1 - Application Communication Status LED

Not Used/Always Off

2.

LED #2 - Fieldbus On-line

LED #2 indicates if the module is On-Line
or not. If the module is On-Line and data
exchange is possible the LED is green.

3.

LED #3 - Fieldbus Off-Line

The LED indicates that the module is Off-
Line and is the opposite of LED #2. If the
module is Off-Line and no data exchange
is possible, this LED is red, otherwise it is
turned off.

4.

LED #4 - Fieldbus Diagnostics

The LED indicates certain faults on the
fieldbus side.

Removing the Profibus Option Card

Step 1. Disconnect the DB9 Serial connector.
Step 2. Use a phillips head screw driver and remove the

two (2) screws that fasten the Profibus Option Card
panel to the HI 3000 Chassis.

Step 3. Using the thumb and index finger on both hands,

grasp the two (2) knobs on the card panel and pull
away from the instrument.

Step 4. When the Profibus Option Card clears the chassis,

store in a static free, safe location.

NOTE:

For Configuration instructions see the Network/
Profibus I/O section of this manual. The installa-
tion for all HI 3000 Series instruments is the
same.

Analog Output Option Card Installation

CAUTION: M

AKE

SURE

THAT

YOU

USE

AN

ANTI

-

STATIC

STRAP

WHEN

INSTALLING

THE

A

NALOG

O

PTION

C

ARD

.

Step 1. Position the Analog Option Card with the back

plane connector facing Option Slot #0 or Option
Slot #1. (See Fig. 78)

LED State

Indicates

Off

-Bus is not On-Line
-No power to the Module

Green

Bus is On-Line and data exchanges is
possible. Fieldbus

TABLE 14: LED #2 - FIELDBUS ON-LINE

LED State

Indicates

Off

-Bus is not Off-Line
-No power to the module

Red

Bus is Off-Line, fieldbus running bit
cleared in AnyBus status.

TABLE 15: LED #3 - FIELDBUS OFF-LINE

1

2

3

4

LED State

Indicates

Off

-No diagnostics Present
-No power to the module.

Flashing Red 1 Hz

Bus is Off-Line. Fieldbus Config Error running
bit set in AnyBus status

Flashing Red 2 Hz

Error in parameter data. Fieldbus Config Error
bit set in AnyBus status

Flashing Red 4 Hz

Error in initialization of the Profibus communi-
cation ASIC. Fieldbus ASIC Error bit set in
AnyBus status

TABLE 16: LED #4 - FIELDBUS DIAGNOSTICS