Selecting source, Mapping the source to the, Hfo - float variables/entering – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 72: Ardy modbus-link display/selecting display/float

Advertising
background image

HI-3000 Series

58

Operation and Installation

•

Click on Modbus Float In (MFI0). (See
Fig. 171)

•

Keep the default word 0.

•

Click on the Select button. The Destina-
tion and Source appear in the Map: text
field. (HFO4=MFI0)

FIG. 171: MAPPING DISPLAY/SELECTING SOURCE

- MFI0 (MODBUS FLOAT IN - WORD 0)

•

Click on the Map button. The Destination
and Source are mapped to the HI 3000
module. To recap we mapped the Modbus
Float In, word 0 to Hardy Float Out, Word
4). (See Fig. 172)

FIG. 172: MAPPING DISPLAY/MAPPING THE

SOURCE TO THE DESTINATION

•

Double click in the HFO (Hardy Float
Out) text field 0.

•

Type in a value. For our example we used
the value “555.0000”. (See Fig. 173)

FIG. 173: MAPPING DISPLAY/HFO - FLOAT

VARIABLES/ENTERING A VALUE FOR WORD 0

•

Click on the Enter button.

•

Go to the Hardy Modbus-Link Display.
(See Fig. 174) Minimize the Web Page, do
not close the browser.

FIG. 174: HARDY MODBUS-LINK DISPLAY/

SELECTING DISPLAY/FLOAT INVERSE

•

Click on the Display pull down menu. (See
Fig. 174)

•

Click on Float Inverse. The value we
entered from the Mapping page appears to
the right of the “00000 =” which is
“555.0000” (See Fig. 175)