Indicators

The following describes each ON/OFF condition of indicator when LIGHT-ON (L) is set.

When the DARK-ON (D) is set, the output indicator ON/OFF will reverse.

Mutual interference

For reflective type / retro-reflective type sensors, mutual interference protection can be set for
up to 2 units. However, when the sensors are mounted facing each other, change the angle of
the sensor head to prevent light being emitted into each unit.(The mark detection type does not
include the mutual interference function.)

Mutual interference prevention can be set when mounting a polarizing filter attachment
(optional with thrubeam type sensors) (If operation is unstable even after mounting the
polarizing filter, slightly lower the sensitivity.)

For more detailed information about mutual interference or attachment, see the PZ-G Series
catalog or contact your nearest KEYENCE office.

*1 The detection distance is measured with the maximum sensitivity.
*2 The cable for the connector type / pigtail quick disconnect type is sold separately. The reflector for the retro-reflective type is sold separately.

KEYENCE products are strictly factory-inspected. However, in the event of a failure, contact your
nearest KEYENCE office with details of the failure.

1. WARRANTY PERIOD

The warranty period shall be for one year from the date that the product has been delivered to
the location specified by the purchaser.

2. WARRANTY SCOPE

(1) If a failure attributable to KEYENCE occurs within the abovementioned warranty period, we will

repair the product, free of charge. However, the following cases shall be excluded from the
warranty scope.
• Any failure resulting from improper conditions, improper environments, improper handling,

or improper usage other than described in the instruction manual, the user’s manual, or the
specifications specifically arranged between the purchaser and KEYENCE.

• Any failure resulting from factors other than a defect of our product, such as the purchaser’s

equipment or the design of the purchaser’s software.

• Any failure resulting from modifications or repairs carried out by any person other than

KEYENCE staff.

• Any failure that can certainly be prevented when the expendable part(s) is maintained or

replaced correctly as described in the instruction manual, the user’s manual, etc.

• Any failure caused by a factor that cannot be foreseen at a scientific/technical level at the

time when the product has been shipped from KEYENCE.

• Any disaster such as fire, earthquake, and flood, or any other external factor, such as

abnormal voltage, for which we are not liable.

(2) The warranty scope is limited to the extent set forth in item (1), and KEYENCE assumes no

liability for any purchaser’s secondary damage (damage of equipment, loss of opportunities,
loss of profits, etc.) or any other damage resulting from a failure of our product.

3. PRODUCT APPLICABILITY

KEYENCE products are designed and manufactured as general-purpose products for general
industries.
Therefore, our products are not intended for the applications below and are not applicable to
them. If, however, the purchaser consults with us in advance regarding the employment of our
product, understands the specifications, ratings, and performance of the product on their own
responsibility, and takes necessary safety measures, the product may be applied. In this
case, the warranty scope shall be the same as above.
• Facilities where the product may greatly affect human life or property, such as nuclear

power plants, aviation, railroads, ships, motor vehicles, or medical equipment

• Public utilities such as electricity, gas, or water services
• Usage outdoors, under similar conditions or in similar environments

E 1040-1

Reference

Green indicator
light

130%*

80%*

Green indicator
light

* For PZ-G62, the upper limit is 107% and the lower limit is 93%.

100%
threshold
value

Received light intensity

Light indicator

(only PZ-G51/52 Series)

Output

Indicator

Stable operation

indicator

Orange

indicator light

Red indicator

light

LIGHT-OFF

LIGHT-OFF

LIGHT-OFF

If the stable operation indicator turns off during operation, readjust or fine-adjust the sensitivity.

Specifications

Type

Thrubeam

Reflective

Retro-reflective

Mark detection

Normal

High-power

Diffuse-reflective

Long-detecting

distance

Diffuse-reflective

Short-detecting

distance

Narrow-view

reflective

Definite

reflective

Long detecting

distance

(with P.R.O. function)

Transparent target

detection

(without P.R.O. function)

Red

Green

Blue

Configuration Cable shape

Output

mode

Rectangular

Cable

NPN

PZ-G51N

PZ-G52N

PZ-G41N

PZ-G42N

PZ-G101N

PZ-G102N

PZ-G61N

PZ-G62N

-

PNP

PZ-G51P

PZ-G52P

PZ-G41P

PZ-G42P

PZ-G101P

PZ-G102P

PZ-G61P

PZ-G62P

M8 connector

NPN

PZ-G51CN

PZ-G52CN

PZ-G41CN

PZ-G42CN

PZ-G101CN

PZ-G102CN

PZ-G61CN

PZ-G62CN

PZ-G10RCN

PZ-G10GCN

PZ-G10BCN

PNP

PZ-G51CP

PZ-G52CP

PZ-G41CP

PZ-G42CP

PZ-G101CP

PZ-G102CP

PZ-G61CP

PZ-G62CP

PZ-G10RCP

PZ-G10GCP

PZ-G10BCP

M12 pigtail quick

disconnect

NPN

PZ-G51EN

PZ-G52EN

PZ-G41EN

PZ-G42EN

PZ-G101EN

PZ-G102EN

PZ-G61EN

PZ-G62EN

-

PNP

PZ-G51EP

PZ-G52EP

PZ-G41EP

PZ-G42EP

PZ-G101EP

PZ-G102EP

PZ-G61EP

PZ-G62EP

Nut

Cable

Bipolar

(NPN+PNP)

PZ-G51B

PZ-G52B

PZ-G41B

PZ-G42B

PZ-G101B

PZ-G102B

PZ-G61B

PZ-G62B

M12 connector

PZ-G51CB

PZ-G52CB

PZ-G41CB

PZ-G42CB

PZ-G101CB

PZ-G102CB

PZ-G61CB

PZ-G62CB

Detecting distance

*1

20 m

40 m

1 m

(30

× 30 cm

white mat paper)

300 mm

(10

× 10 cm

white mat paper)

200 mm

5 to 45 mm

0.1 to 4.2 m

(when R-2L

reflector is used)

0.1 to 1 m

(when R-2L

reflector is used)

8 to 15 mm

Spot diameter

-

-

-

-

Approx.

φ 5 mm

(when the detecting

distance is 100 mm)

Approx.

φ 2 mm

(when the detecting

distance is 40 mm)

-

-

Approx. 1.5

× 4 mm

(when the detecting distance is 10 mm)

Light source (LED)

Red LED

Infrared LED

× 2

Red LED

Infrared LED

Red LED

Green LED

Blue LED

Sensitivity adjustment

1-turn trimmer (230 degrees)

Response time

500 μs

50 μs

Operation mode

LIGHT-ON/DARK-ON, trimmer-selectable

Indicator (LED)

Transmitter: power (orange)

Receiver: output (orange),

stable operation (green),

light (red)

Output (orange), stable operation (green)

Control output

Open-collector 100 mA max. (30 V max.), Residual voltage 1 V max.

Protection circuit

Reverse-polarity protection, over-current protection, output surge absorber

Ratings

Power voltage

10 to 30 VDC, Ripple (P-P): ±10% max, Class 2.

Current consumption

Transmitter: 20 mA

max.

Receiver: 28 mA max.

Transmitter: 25 mA

max.

Receiver: 28 mA max.

34 mA max.

Environmental

resistance

Enclosure rating

IEC,JEM: IP67 / NEMA: 4X,6,12 / DIN: IP69K

Ambient light

Incandescent lamp: 5,000 (lx) max, Sunlight: 20,000 (lx) max.

Ambient temperature

-20

°C to +55°C (No freezing)

Relative humidity

35 to 85

% RH (No condensation)

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude in X, Y, Z directions, 2 hours each

Shock resistance

1000 m/s

2

in X, Y, Z directions, 6 times each

Interference prevention

2 units

(when polarizing filter attachment is used)

2 units (with the automatic different cycle function)

-

Material

Case, M18 nut (nut type only): reinforced glass polybutylene terephthalate (PBT), Trimmer: reinforced glass polyamide (PA)

Cable (Cable type / pigtail quick disconnect type only): Polyvinyl chloride (PVC), Screw (Case connection): Steel, zinc-nickel plated, Packing (Case connection): Nitrile-butadiene rubber (NBR)

Connector (pigtail quick disconnect type only): Brass-nickel plated, Polybutyleneterephtalate (PBT), Polyvinyl chloride (PVC)

Lens cover

Polyarylate (PAR)

Acrylic plastic

(PMMA)

Polyarylate (PAR)

Tightening torque

Rectangular type (side screw part): 0.5 N·m max. Nut type (front M18 part): 1.0 N·m max., (side slot part): 0.5 N·m max.

Accessory

*2

Instruction manual, M18 nut x 2 (nut thrubeam type), M18 nut x 1 (other nut types)

Weight

Rectangular cable type: Approx. 60 g (Approx. 50 g for thrubeam transmitter), Rectangular M8 connector type: Approx 10 g, rectangular M12 pigtail quick disconnect type: Approx. 30 g

Nut type cable type: Approx. 65 g (Approx. 55 g for thrubeam transmitter), Nut type M12 connector type: Approx 15 g

WARRANTY

Advertising