Output Switch

Either light-ON (L-on) mode or dark-ON (D-on) mode can be selected.

1

While the current value is displayed, press the [MODE] button once.

2

Use

to switch the output (

.QP

/

&QP), then press the [MODE] button again.

The output change completes, and the display returns to the current value.

Connecting to External Devices

„

Cable Types

„

M8/e-CON Connector Types

„

M8 connector Cable (Sold Separately)

For FS-N11CN/N11CP/N12CN/N12CP/N13CP/N14CP

Error Displays and Corrective Actions

Consult your nearest KEYENCE office regarding error displays other than the ones listed above.

Initializing the Settings

„

Initialization Method

1

Press and hold the [SET] and [PRESET] buttons simultaneously for three seconds.

2

Use the

to select "

456", then press the [MODE] button.

3

Use the

to select "

K0K6", then press the [MODE] button.

After initialization is complete, the display returns to the current value.

z

Initial Settings

Using a Fiber Cutter and Cautions for Use

„

Using a Fiber Cutter

1

Insert the fiber into the cutter hole.

2

Bring down the blade in a single,
swift motion to cut the fiber.

„

Cautions for Using a Fiber Cutter

The fiber cutter comes with the fiber unit.

When cutting a fiber unit to be attached to the FS-N10 Series, be sure to use a gray fiber cut-
ter (OP-87098)

Stopping the blade midway could cause a bad cut plane, reducing the detection range.

Do not use the same hole twice.

Function Configuration

„

Basic Setting

*1 You can press the

button to set between the range of

2 to 2.

FS-N11N/N12N/N13N/N14N

FS-N11P/N12P/N13P/N14P

*1 FS-N11N/N13N only
*2 FS-N13N/N14N only

*1 FS-N11P/N13P only
*2 FS-N13P/N14P only

FS-N11MN

FS-N11CN/N12CN/N11EN/N12EN

FS-N11CP/N12CP/N13CP/N14CP

*1 FS-N11CN/N11EN only

*1 FS-N11CP/N13CP only
*2 FS-N13CP/N14CP only
*3 FS-N11CP/N12CP only

Error display

Cause

Solution

ErC

Overcurrent in the control output.

Check the load and return the current
within the rated value.

ErE

Failed to write/load the internal data. Perform initialization (p.4).

End APC

Large load on the light source.

Replace the sensor if highly precise
detection is required.

Loc

The keylock function is ON.

For disabling (setting) method, see
"FS-N10 Series User's Manual".

12 to 24 VDC

DC3.3V

Black

(Control output 1)

(Control output 2)

PLC, etc.

White

Pink

*2

*2

Brown

*1

0V

Load

Load

Blue

*1

Sensor main circuit

Overcurrent

protection circuit

(Short-circuit
current 1 mA
or less)

12 to 24 VDC

Black

(Control output 1)

(Control
output 2)

*2

PLC, etc.

White

Pink

*2

Brown

*1

0V

Load

Load

Blue

*1

Sensor main circuit

Overcurrent

protection circuit

(Short-circuit
current 2 mA
or less)

0 V

Brown

Black

Monitor output (1 to 5V)

Orange

Load

Blue

(Control output)

12 to 24 VDC

Device with input
impedance
10 k

Ω or more

Protection

circuit

Sensor main circuit

Overcurrent

protection circuit

*1

*1

DC3.3V

Sensor main circuit

Overcurrent

protection circuit

12 to 24 VDC

PLC, etc.

0V

(Short-circuit
current 1 mA
or less)

PLC, etc.

0V

(Short-circuit
current 1 mA
or less)

(Control output)

Load

*3

*1

*1

Sensor main circuit

Overcurrent

protection circuit

12 to 24 VDC

PLC, etc.

0V

(Short-circuit
current 2 mA
or less)

(Control output 1)

(Control
output 2)

*2

Load

Load

1

2

3

4

M8 connector Pin layout

FS-N11CN/N12CN

e-CON connector Pin layout

FS-N11EN/N12EN

1

2

3

4

M8 connector Pin layout

OP-73864
(Cable length: 2 m)

OP-73865
(Cable length: 10 m)

1

2

3

4

Connected

pin No.

Pin - Pin and wire color table

1

Brown

2

3

4

White

Blue

Black

Wire color

Setting

Initial Value

Power mode

FINE

Detection mode

Std (Normal)

Setting value

50

Output switch

L-on

Failure to follow the cautions below could reduce the detection range.

Press and hold for 3 seconds or more

Fiber

Always insert fiber from the side with writing

Fiber cutter
(OP-87098)

2

1

MODE

Press and hold for 3 seconds or more

HIGH SPEED mode

FINE mode

TURBO mode

SUPER mode

ULTRA mode

MEGA mode

Normal sensitivity setting method

Percentage Calibration*

1

Zero-shift calibration

Settings complete

Go to detection setup mode

Go to display setup mode

Go to system setup mode

MODE

MODE

MODE

MODE

J52

(KPG

6WT$

5W24

7.64

/')#

5V)

5V)

5V)

5'6













5VF

5'V2

15'V

'0&

(W0E

&K52

5;5

5'6

5'6

Return to normal display

MODE