Specifications, Error displays and corrective actions, Hints on correct use – KEYENCE FS-V34C(P) User Manual

Page 8: Warranty, Warranty period, Warranty scope, Product applicability

Advertising
background image

8

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.

11292E 1070-1 96M11292 Printed in Japan

Specifications

*1

When several units are connected, the operating ambient temperature varies depending
on the number of units to be connected. When connecting several units, be sure to
mount the units on the DIN rail (mounted on a metal plate), and keep the output current
within 20 mA.
When 1 to 2 units are connected:

-10 to +55 °C,

When 3 to 10 units are connected:

-10 to +50 °C,

When 11 to 16 units are connected: -10 to +45 °C
When using the 2-output type, count one unit as two units.

*2

When double is set, the response time is twice longer. When using the 2-output type, be
careful with the number of units to be connected.

*3

When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA).

Error Displays and Corrective Actions

Hints On Correct Use

• Do not wire the amplifier line along with power lines or high-tension lines, other-

wise the sensor may malfunction or receive damage due to noise.

• When using a commercially available switching regulator, ground the frame

ground terminal and ground terminal.

• Do not use the FS series outdoors, or in a place where extraneous light can

enter the light-receiving surface directly.

• Due to the individual dispersion of characteristics and the difference in fiber

unit model, the maximum sensing distance or displayed value of all the units
are not the same.

• If the sensor is used in S-APC mode for a long time, the LED indicators will be imposed

with a heavy load. In that case, the sensor will be automatically set to ACC mode where
the current consumption of the sensor for light emission will be constant, and “END
APC” will be displayed. The sensor can be continuously used in this case. Replace the
sensor, however, if highly precise detection is required.

WARRANTY

KEYENCE products are strictly factory-inspected. However, in the event of a failure,
contact your nearest KEYENCE office with details of the failure.

1. WARRANTY PERIOD

The warranty period shall be for one year from the date that the product has been
delivered to the location specified by the purchaser.

2. WARRANTY SCOPE

(1) If a failure attributable to KEYENCE occurs within the abovementioned warranty

period, we will repair the product, free of charge. However, the following cases shall
be excluded from the warranty scope.
• Any failure resulting from improper conditions, improper environments, improper

handling, or improper usage other than described in the instruction manual, the
user’s manual, or the specifications specifically arranged between the purchaser
and KEYENCE.

• Any failure resulting from factors other than a defect of our product, such as the

purchaser’s equipment or the design of the purchaser’s software.

• Any failure resulting from modifications or repairs carried out by any person other

than KEYENCE staff.

• Any failure that can certainly be prevented when the expendable part(s) is

maintained or replaced correctly as described in the instruction manual, the user’s
manual, etc.

• Any failure caused by a factor that cannot be foreseen at a scientific/technical

level at the time when the product has been shipped from KEYENCE.

• Any disaster such as fire, earthquake, and flood, or any other external factor, such

as abnormal voltage, for which we are not liable.

(2) The warranty scope is limited to the extent set forth in item (1), and KEYENCE

assumes no liability for any purchaser’s secondary damage (damage of equipment,
loss of opportunities, loss of profits, etc.) or any other damage resulting from a failure
of our product.

3. PRODUCT APPLICABILITY

KEYENCE products are designed and manufactured as general-purpose products
for general industries.
Therefore, our products are not intended for the applications below and are not
applicable to them. If, however, the purchaser consults with us in advance regarding
the employment of our product, understands the specifications, ratings, and
performance of the product on their own responsibility, and takes necessary safety
measures, the product may be applied. In this case, the warranty scope shall be the
same as above.
• Facilities where the product may greatly affect human life or property, such as

nuclear power plants, aviation, railroads, ships, motor vehicles, or medical
equipment

• Public utilities such as electricity, gas, or water services
• Usage outdoors, under similar conditions or in similar environments

E 1040-1

Type

Cable type

Connector type

Main unit

Sub unit

Main unit

Sub unit

Model

NPN output

FS-V33

FS-V34

FS-V33C

FS-V34C

PNP output

FS-V33P

FS-V34P

FS-V33CP

FS-V34CP

Light source

Red 4-element LED (peak wave length: 640 nm typ.)

Control

output

NPN output

NPN open collector 24 V 100 mA (2CH total) max

(2 outputs)

*1

PNP output

PNP open collector 24 V 100 mA (2CH total) max

Response time

ON/OFF

output

33 μs (HIGH SPEED)/250 μs (FINE)/500 μs (TURBO)/

1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)

Control input

Calibration/Scaling/

Zero-shift/Reset/Emission

stop(input time ON: 2 ms, OFF:

20 ms)

Number of

interference

prevention

units

Normal time

When

double is set

*2

Timer function

Timer OFF/Off-delay/On-delay/One-shot/

On-delay Off-delay/On-delay One-shot

(Timer time: 0.1 ms to 9999 ms)

Power voltage

12-24 VDC, Ripple (P-P): 10% max, Class2

Power

consumption

*3

NPN output

Normal: 710 mW max. (Using 24 V, 29 mA max., using 12 V, 40 mA max.)
Power saving: 540 mW max. (Using 24 V, 22 mA max., using 12 V, 28 mA

max.)

PNP output

830 mW max. (Using 24 V, 35 mA max., using 12 V, 45 mA max.)/

Power saving 660 mW max. (Using 24 V, 27 mA max., using 12 V, 32 mA max.)

Operating

ambient

luminance

Incandescent

lamp

20,000 lx max.

Sun light

30,000 lx max.

Operating ambient tempera-

ture

-10 to +55 °C (No freezing)

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration resistance

10 to 55 Hz Compound amplitude 1.5 mm,

2 hours for each of XYZ axes

Shock resistance

500 m/s

2

3 times for each of XYZ axes

Material

Main unit, housing material: Polycarbonate

Weight (including cable)

Approx. 80g

Approx. 70g

Approx. 22g

Error display

Cause

Corrective action

'T=

Overcurrent is flowing in the control
output.

Check the load and return the current
within the rated value.

'T'

Failed to write/read the internal data.

Perform initialization (p.2).

'PF#2=

The load on the light source is large.

If highly precise detection is required,
replace the sensor.

Power mode

HIGH SPEED

FINE

TURBO/SUPER/ULTRA/MEGA

Number of units

required to pre-

vent interference

0 units

4 units

8 units

Power mode

HIGH SPEED

FINE

TURBO/SUPER/ULTRA/MEGA

Number of units

required to pre-

vent interference

0 units

8 units

16 units

Advertising
This manual is related to the following products: