Setting sensitivity, Change the setting value, 2setting sensitivity – KEYENCE FS-V1(P) User Manual

Page 2: For sensitivity adjustment using a moving target, For target positioning, For stable detection unaffected by dust, Increase sensitivity (=decrease the setting value), Decrease sensitivity (=increase the setting value)

Advertising
background image

2

SETTING SENSITIVITY

Select the sensitivity setting procedure according to the target condi-
tion.

For sensitivity adjustment using a moving target

z

Fully-automatic Calibration

To detect a minute difference

z

Two-point Calibration

For target positioning

z

Positioning Calibration

For stable detection unaffected by dust

z

Maximum Sensitivity Setting

CHANGE THE SETTING VALUE

You can change the setting value in “excess gain display” mode or “set-
ting value display” mode.

Increase sensitivity (=Decrease the setting value)

z

In excess gain display mode

The sensitivity increases by 1% each time you press

[UP].

z

In setting value display mode

The setting value decreases by 1 each time you press

[DOWN].

Decrease sensitivity (=Increase the setting value)

The method for decreasing the sensitivity is the same as for increasing
the sensitivity, except you must press

[DOWN] instead.

CUE: Holding down [UP] or [DOWN] changes the setting value rapidly.

For sensitivity adjustment using an external signal

z

External Calibration Function

1. Hold down

[MODE] and [UP] simultaneously for 3 seconds to display

“Loc”. (If “vnL” appears, repeat the same procedure.)

2. Connect the pink cable to a switch or PLC.

The minimum input time is 20 ms.

3. The external calibration procedure is the same as using the

SET but-

ton. Turn the input device on instead of pressing the

SET button.

Also, turn the input device off instead of releasing the

SET button.

(You can perform all the setting procedures described on the left.)

1. Pass a target through the

optical axis while press-
ing the SET button.

2. Confirm that the calibra-

tion indicator (yellow LED)
flashes.

3. Release the SET button.

The calibration indicator
(yellow LED) goes off.

1. With a target in place, press

the SET button and release it.
The calibration indicator (yel-
low LED) lights.

2. With the target removed,

press the SET button and
release it. The calibration
indicator (yellow LED) goes
off.

1. With no target, press the

SET button and release it.
The calibration indicator
(yellow LED) lights.

2. Place a target in the posi-

tion where it is to be
stopped.

3. Press the SET button until

the calibration indicator
flashes.

4. Release the SET button.

1. Under the following con-

ditions press the SET
button until the calibration
indicator (yellow LED)
flashes.

2. Release the SET button.

The calibration indicator
(yellow LED) goes off.

CUE: When the sensitivity difference is insufficient
If sensitivity has no allowance after calibration, “------” flashes for 3
seconds on the LCD display monitor.
Note: Sensitivity is set and registered even when the sensitivity differ-
ence is insufficient. Be sure to confirm that detection is properly per-
formed.

CUE: Locking the operation button (Key protect)
Hold down

[MODE] and [UP] simultaneously for 3 seconds to lock the

operation button. When the operation button is locked, “Loc” is dis-
played in flashing letters.
To unlock the operation button, repeat the procedure above. “vnL”
(unlocked) is displayed in flashing letters.
Even when the operation button is locked, display data and channel
can be changed.

A

B

MODE

SET

#

2

CH

At least
3 seconds

A

B

MODE

SET

#

2

CH

At least
3 seconds

At least
3 seconds

A

B

MODE

SET

#

2

CH

Reflective type

Thrubeam type

With no target

With target

CUE: Calibration input during detection
You can re-adjust sensitivity during detection without stopping the
operation.
The sensor continues operation with the previous sensitivity setting
until sensitivity readjustment is completed.

CUE: External calibration with several units
When several units are connected, the sensitivity of all the FS-T2(P)
expansion units can be simultaneously set using the external calibra-
tion input through the FS-V1(P).
You can select a unit to be externally calibrated by setting its key pro-
tection switch to the LOCK position.
External calibration is effective for all the units which are locked. Set
the key protection switch to LOCK on the FS-T2(P) expansion unit to
be externally calibrated.

MODE

SET

#

2

CH

MODE

SET

#

2

CH

MODE

SET

#



CH

MODE

SET

#



CH

MODE

SET

#

2

CH

NPN

+V

0V

Pink

Blue

Brown

Contact or
solid-state input

PNP

+V

0V

Pink

Blue

Brown

Contact or solid state input