6 dp-v1 service, Execu ting communi cat ion – KEYENCE DL-PD1 User Manual

Page 53

Advertising
background image

3-6

DP-V1 Service

3-31

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -

Execu

ting Communi

cat
ion

3

139

Measurement direction

DINT

R/W

0

0: Normal
1: Reverse

140

Multiplier

DINT

R/W

001.0

000.1 to 100.0

141

Output mode

DINT

R/W

0

0: NO
1: NC

142

Display resolution

DINT

R/W

0

0: 0.0001
1: 0.001
2: 0.01
3: 0.1

143

Hysteresis

DINT

R/W

+000.003

000.000 to +999.999

144

Input (purple wire) func. 1

DINT

R/W

0

0: Bank A
1: Reset

145

Input (pink/purple wire) func.
2

DINT

R/W

0

0: Timing input
1: Bank B

146 to

148

Reserved for system

149

Preset memory

DINT

R/W

0

0: YES
1: NO

150

Reserved for system

151

Power-saving function (ECO)

DINT

W

0

0: OFF
1: HALF
2: ALL

152

Jam detection function

DINT

R/W

0

0: OFF
1: ON
2: USER

153

Check point setting

DINT

R/W

+000.500

-65.534 to +65.534

154

Display filter function

DINT

R/W

0

0: ON
1: OFF

155 to

159

Reserved for system

160

Group5 Entry count

DINT

R

10

161

R.V. (base of calc.) ID01

*3

*10

DINT

R

162

R.V. (base of calc.) ID02

*3

*10

DINT

R

163

R.V. (base of calc.) ID03

*3

*10

DINT

R

164

R.V. (base of calc.) ID04

*3

*10

DINT

R

165

R.V. (base of calc.) ID05

*3

*10

DINT

R

166

R.V. (base of calc.) ID06

*3

*10

DINT

R

167

R.V. (base of calc.) ID07

*3

*10

DINT

R

168

R.V. (base of calc.) ID08

*3

*10

DINT

R

169

R.V. (base of calc.) ID09

*3

*10

DINT

R

170

R.V. (base of calc.) ID10

*3

*10

DINT

R

171 to

191

Reserved for system

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value

Advertising