E DL-PN1_IM

Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.

13277E 1104-1a 96M13277 Printed in Japan

(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for

a period of one (1) year from the date of shipment. If any models or samples were shown

to Buyer, such models or samples were used merely to illustrate the general type and

quality of the Products and not to represent that the Products would necessarily conform

to said models or samples. Any Products found to be defective must be shipped to

KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection

and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will

refund the purchase price of, or repair or replace at no charge any Products found to be

defective. This warranty does not apply to any defects resulting from any action of Buyer,

including but not limited to improper installation, improper interfacing, improper repair,

unauthorized modification, misapplication and mishandling, such as exposure to

excessive current, heat, coldness, moisture, vibration or outdoors air. Components

which wear are not warranted.

(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are

only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products

for Buyer’s intended use. KEYENCE will not be responsible for any damages that may

result from the use of the Products.

(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be

used internally in humans, for human transportation, as safety devices or fail-safe

systems, unless their written specifications state otherwise. Should any Products/

Samples be used in such a manner or misused in any way, KEYENCE assumes no

responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE

harmless from any liability or damage whatsoever arising out of any misuse of the

Products/Samples.

(4)

OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE

PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,

IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT

LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A

PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY

RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE

AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY

FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR

CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY

DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION,

LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF

PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF

SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY

MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR

INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS

AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S

CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER.

In some

jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not

apply.

BUYER'S TRANSFER OBLIGATIONS:

If the Products/Samples purchased by Buyer are to be resold or delivered to a third party,

Buyer must provide such third party with a copy of this document, all specifications,

manuals, catalogs, leaflets and written information provided to Buyer pertaining to the

Products/Samples.

E 1101-3

Dimensions

Specifications

Product name

PROFINET I/O Communication Unit

Model

DL-PN1

Suitable network

PROFINET I/O communication

Ethernet

Compliant standards

IEEE 802.3u (100BASE-TX)

Transmission rate

100 Mbps (100BASE-TX)

Transmission medium STP cable or Category 5e or higher UTP cable

(100BASE-TX)

Maximum cable

length

100 m

PROFINET

Compatible functions

Data I/O communication

Record data communication

No. of connectable

PROFINET I/O

controllers

1

Update Time

2 - 512 ms

GSDML version

V2.3

Conformance class

Conforms with Conformance Class A

Conformance test

version

Conforms with V2.2.4

Suitable protocols

LLDP, DCP

Sensor

connection

specifications

Connectable sensors

Sensor amplifiers with D-bus support

Number of

connectable sensor

units

15 units max.

Indicator lamps

Link/activity indicator (LINK/ACT): Green LED

System failure indicator (SF):

2-color (orange/red) LED

Bus failure indicator (BF): Red LED

Sensor communication indicator (D-bus):

2-color (green/red) LED

Power voltage

20 to 30 V DC ±10%, including ripple (p-p)10%

supplied from the connected sensor amplifiers

Power consumption

1500 mW or less (at 30 V 50 mA max.)

Environmental

resistance

Operating surrounding

air temperature

-20 to +55°C (no freezing)

Operating surrounding

air humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 55 Hz compound amplitude 1.5 mm, 2

hours each in X, Y, Z directions

Pollution degree

2

Materials

Main unit: Polycarbonate

Weight

Approx. 70 g

25.6

35.4

43.5

94.5

38.1

(42.5

)

29.4

(Unit : mm)