Reference programs, Read comparator value (p.v. value), Input preset – KEYENCE DL-PN1 User Manual
Page 27: Explanation of the program
Advertising

25
- PROFINET Communication Unit DL-PN1 User's Manual (GT) -
Reference programs
This section introduces reference programs for carrying out PROFINET communication.
If you use these program, ensure that error handling etc. is taken into account when
programming.
Read comparator value (P.V. value)
Explanation of the program
M6.0 (Address 6, Bit 0) turns ON.
The amplifier (main unit) comparator value (P.V. value) is written to MD40.
Input PRESET
Explanation of the program
M6.0 (Address 6, Bit 0) turns ON.
When the amplifier (main unit) comparator value property (Address 17, Bit 1) is Valid (0),
ZERO SHIFT (Address 1, Bit 0) is performed.
MOV
M6.0
EN
ENO
IN
OUT
ID19
MD40
Network1
M6.0
I 17.1
Q 1.0
S
Network1
Advertising