KEYENCE DL-RS1A/FD-MH User Manual

Page 17

Advertising
background image

15

Communication Response Time

T4 (DL-RS1A command processing time)

The processing time varies according to the command sent from the external device.

Read commands

Write commands

Communication command

Number of connected

sensor amplifiers

Command processing time (T4)

FD-MH Series

SR

1

14 ms

2

15 ms

3

17 ms

4

18 ms

5

20 ms

6

21 ms

7

23 ms

8

24 ms

9

26 ms

10

27 ms

M0/MS/DRQ input

1 to 10

4 ms

Communication command

Number of connected

sensor amplifiers

Command processing time (T4)

FD-MH Series

SW

1

14 ms

2

15 ms

3

17 ms

4

18 ms

5

20 ms

6

21 ms

7

23 ms

8

24 ms

9

26 ms

10

27 ms

AW

1

57.5 ms

2

58.5 ms

3

60.5 ms

4

61.5 ms

5

63.5 ms

6

64.5 ms

7

66.5 ms

8

67.5 ms

9

69.5 ms

10

70.5 ms

Communication Response Time

T5 (Response send time from DL-RS1A)

The time required to send a response varies depending on the communication speed, data bit
length, and number of bytes.
For information on the communication settings, refer to page 2.
The response time can be calculated using the following formula:

T5 = (number of bytes) x (data bit length + 4) / (communication speed)

Number of bytes for different commands

SR command : (number of bytes in the read data) + 12
M0 command : {(number of bytes in the read data) + 1} u number of connected sensor amplifiers + 4
MS command : {(number of bytes in the read data) + 3} u number of connected sensor amplifiers + 4
DRQ input

: {(number of bytes in the read data) + 3} u number of connected sensor amplifiers + 4

SW command : 11
AW command : 8
* For information on the number of bytes in the write data and the number of bytes in the read data,

refer to "Parameters of Commands and Responses" (page 10).

Sample calculation

T6 (Sensor amplifier settings change time)

For information on the calculation function, refer to the manual supplied with the sensor amplifiers.

When calculation function of sensor amplifiers is OFF

T6 = 0 ms for SW and AW commands; the sensor amplifiers complete modifying their settings during
the T4 period.
* This table also applies to the sensor amplifiers that do not have the calculation function.

When calculation function of sensor amplifiers is ON

SW and AW commands both require the processing time shown below.

Number of bytes

Data length

Communication speed

Response time

21

8 bit

9600 bps

26 ms

114

8 bit

9600 bps

143 ms

21

7 bit

38400 bps

6 ms

114

7 bit

38400 bps

33 ms

Number of connected sensor amplifiers

Settings change time (T6)

1

7 ms

2

9 ms

3

13 ms

4

15 ms

5

19 ms

6

21 ms

7

25 ms

8

27 ms

9

31 ms

10

33 ms

Advertising