3

After 4 sec

of no key

operation.

Reference value*

Press for 3 sec or more.

+

+

Increase the
setting.

Decrease the
setting.

Operating mode

Standard

Focus mode

AP-

C30W(P)

only

AP-C31W(P)/

C33W(P)

When

operating

mode is

• Two-point tuning
• Active tuning

Display color (7-segment)

ON: Red, OFF: Green

ON: Green, OFF: Red

Normally red

Normally green
Within set value: Green
Outside set value: Red

Detection range (AP-C30W(P) only)

Units

Positive pressure range

Compound pressure range

Negative pressure range

Focus center pressure

Toggling the
display

Manual configuration

Settings are
manually
configured. The
display changes
for each mode.
* Toggling the

display of
settings (see the
diagram below).

* Manual

configuration
only during F-3/A-
2 mode operation.

Current value

Peak hold

Bottom hold

* The reference value is

the pressure value when
zero shift input is
received and is replaced
only when zero shift
input is selected.

Mode
configuration

Current value

Reference value

Hold value

Detection mode

General-purpose mode

Variable hysteresis mode

Window mode

Application mode 1

Application mode 2

Zero shift input

Analog output

N.O./N.C.

N.O.

N.O.

N.C.

N.C.

N.O.

N.C.

N.C.

N.O.

Control

output 1

Control

output 2

2.5

msec

5

msec

100 msec

500 msec

Analog/zero shift

Chatter prevention
Sets response time.

• N.O.

= normal open.

• N.C.

= normal close.

Standard

Eco mode

Power-save

* See the Focus Mode section of

Part 9 for the center pressures
that can be selected.

* F-1 and F-2 mode only

Values that fall between the P1
and P2 settings will be displayed
in green, while values outside
that range will be displayed in
red.

*

When

A-1/A-2 is

selected

during
fixed mode
operation

(

)

Pa
kgf/cm

2

(AP-C30/C33 only)

mmHg (AP-C30/C31only)
inHg (AP-C30/C31only)
psi
bar

8. Sensor Configuration

Toggling the display of settings

General-purpose mode/F1

Variable hysteresis mode/F-2

Window mode/F-3

Application mode 1/A-1

Application mode 2/A-2

Two-point tuning (F-1/F-2)

The sensor is made to detect the pressures when the target object is
present and then absent for confirmation of target suction pick-up, and
the intermediate value is used.
Control output 1 configuration: When P1 (H1) is selected on the settings
display.
Control output 2 configuration: When P2 (H2) is selected on the settings
display.

Flashes

for 3 sec.

Setting

Target object

present

Target object

absent

Active tuning (A-1)

See Section 10.

Note:• Press and hold the MODE button (

) for at least 3 seconds to return to the current

value/reference value/hold value display from each of the mode setting screens.

• Press the left side

on the manual adjustment button (

) while holding down the

mode button (

) to return to the previous display.

• The current value will be displayed based on the ambient pressure conditions prevalent

at that time without regard to zero shift input when the P2 setting display is selected for
A-1 mode or when the Hi and Lo setting displays are selected for A-2 mode.

• The sensor must be configured manually when operating in the F-3/A-2 modes. The

SET button (

) will not function.