Key lock, Specifications, Error displays and corrective actions – KEYENCE AP-C40W(P) Series User Manual

Page 5: Default mode settings (initialization), Warranties and disclaimers

Advertising
background image

5

*1 Ambient pressure can be corrected within a range of ±5 % of F.S.

When atmospheric pressure compensation has been performed, the
settings will be saved even when power to the sensor is turned off.

*2 Can also be used when operating in focus mode, although for some

center pressures the display will read FFF.
(Atmospheric pressure compensation is being performed.)

13. Key Lock

Disables operations that would modify the sensor’s configuration. Display
content can be toggled.

Pressing and holding either or for at least 3 seconds while pressing

button will lock the keypad and cause the

display to flash.

* The same key combination will deactivate the key lock feature.

14. Specifications

Sensor head

Model

Environmental

resistance

Units

Pressure resistance

Adaptive fluids

Pressure type

Temperature
characteristics

Pressure port

Housing material

Weight

Ambient temperature

Relative humidity

Vibration

Shock Resistance

Rated pressure range

7 g (not including cables) / 70 g (including

3-m cable) (4.8 g / 67.8 g for AP-41M)

35 g/98 g

10 to 55 Hz, compound amplitude 1.5 mm, 4 hours for each of XYZ axes

35 to 85 % RH (No condensation)

0 to +50

°

C (No freezing)

M5 male screw

PT1/8

Within

±

2 % of F.S. (at 25

°

C)

(in temperature range of 0 to 50

°

C)

Differential

pressure

Gage pressure

Air, non-corrosive gasses

AP-48

500 kPa

500 kPa

1.5 MPa

500 kPa

AP-41/41M

AP-43

AP-44

1,000 m/s

2

, 10 times for each of XYZ axes, total 60 time

Case: PBT; Screws: SUS303

kPa

bar

psi

inHg

mmHg

kgf/cm

2

0 to -101.3

101.3 to -101.3

-101.3 to 101.3

0 to 1.000 MPa

0 to -29.9

0 to -14.69

0 to -1.013

0 to 145.0

0 to 10.00

29.9 to -29.9

14.69 to -14.69

1.013 to -1.013

-1.013 to1.013

-14.69 to 14.69

0 to -760

0 to 10.20

760 to -760

-1.033 to 1.33

Amplifier

Model

Head combination

Display method

Configuration/display

range *1

Operating status indicators

Repeatability

Hysteresis *2

Display temperature
characteristics

Response (chatter
prevention feature)

Zero shift input

Control output

Analog output

Housing material
Weight
Accessories

Power supply voltage

Current
consumption

Vibration

Relative humidity

Ambient temperature

Rating

Resolution

Environmental

resistance

AP-C40W(P)

12 to 24 VDC

±

10% Ripple (P-P) 10% or less

Red 4.5 digit, 7 segment LED display (4.5 mm character height)

AI indicator (green) Display refresh rate: 10 times/sec

-15 to +110 % of F.S.

±

0.2% of F.S. or less

Variable (standard 0.5% of F.S.)

Within

±

1% of F.S. (at +25

°

C)

(within 0 to +50

°

C temperature range)

Selectable from 1, 2.5, 5, 100, 500 ms

Input time 2 ms or greater

(Switchable with analog output.)

NPN open collector Max. 100 mA (40 V or less)

Residual voltage 1 V or less, 2 outputs (NO/NC switchable)

PNP open collector Max. 100 mA (30 V or less) *3

Residual voltage 1 V or less, 2 outputs (NO/NC switchable)

1 to 5 V Output impedance 1 k

Ω or less

(Switchable with zero shift input.)

0 to +50

°

C (No freezing)

35 to 85 % RH (No condensation)

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of XYZ axes

Main unit cover : Polycarbonate

Approx. 80 g (including 2-m cable) / Approx. 35 g (not including cable)

Head connectors, units sticker connector cable

Red LED x 2 (supports control output 1 / control output 2)

12 V operation( NPN/PNP)

780mW (65mA)/960mW (80mA) or less

24 V operation( (NPN/PNP)

1080mW (45mA)/1440mW (60mA) or less

540mW (45mA)/660mW (55mA) or less

840mW (35mA)/1080mW (45mA) or less

AP-41/41M

Normal
Eco mode

AP-43

AP-44

AP-48

Standard mode

High-resolution mode

kPa
kgf/cm

2

mmHg
inHg
psi
bar
kPa
kgf/cm

2

mmHg
inHg
psi
bar

0.1

0.01

0.1

0.1

0.01

0,001

0.001

0.02

1

0.1

0.01

0.001

0.01

0.01

0.1

0.002

0.1 mbar

0.2 mbar

0.001 MPa

0.1

1

0.1

0.02

0.001

0.02

0.2

0.01

0.2 mbar

0.1

0.001

0.02

0.001

0.02

0.2 gf/cm

2

0.004

0.004

15. Error Displays and Corrective Actions

Error displays during normal operation

• No difference in sensitivity

(during 2 point tuning/active
tuning).

• There is an applied pressure

of

±

5 % of F.S. during ambient

pressure compensation.

• There is no sensor head

connected.

• The connection to the sensor head

is broken.

• An excess current is flowing to the

control output.

• Reading is falling below

(exceeding) configuration/display
pressure range.

• Reading is exceeding (falling

below) configuration/display
pressure range.

• When there were not at least 2

shift inputs during active 2 point
tuning.

Adjust the air pressure device so that
there will be a difference in sensitivity.

(Return to atmospheric pressure.)
Repeat atmospheric compensation.

Verify that a sensor head is connected
and turn the power on again.

Repair the sensor head disconnection
and turn the power to the sensor back
on.

Check the load and return it to the
rated range.

Return the pressure to the rated
pressure range.

Return the pressure to the rated
pressure range.

Repeat the active tuning procedure
so that there are at least 2 shift inputs.

Display

Cause

Solution

* Contact KEYENCE for information about error displays other than those

described above.

*1 During focus mode operation, restricted to focus range.
*2 During focus mode operation, standard 0.1% of F.S.
*3 The AP-C40WP uses PNP output.

Copyright (c) 2008 KEYENCE CORPORATION. All rights reserved.

0983E 1022-3 96M0983 Printed in Japan

16. Default Mode Settings (Initialization)

The sensor ships with the following configuration.

Units

Detection mode

Operating mode

N.O./N.C. switching

Analog/zero shift

*

Chatter prevention

Display color

Power-save

*Press

button 5 times while holding down the button to return the

sensor to its default configuration.

KEYENCE, at its sole option, will refund, repair or replace at no charge any
defective Products within 1 year from the date of shipment. Unless stated
otherwise herein, the Products should not be used internally in humans, for
human transportation, as safety devices or fail-safe systems.

EXCEPT FOR

THE FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY

WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF

PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE

SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,

CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT

FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY

SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE. In some
jurisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.

E 1101-3

WARRANTIES AND DISCLAIMERS