Connecting the sensor and pc, Connecting directly, Connecting via network – KEYENCE IV-H1 User Manual

Page 2: Connecting the ethernet cable

Advertising
background image

2

IV Series (IV Software) - IM_E

Connecting the Sensor and PC

Connecting directly

Connect the sensor and PC using the Ethernet cable.

Ethernet cable

(2m/5m/10m)

For details on connecting the Ethernet cable,

refer to “Connecting the Ethernet cable” (Page 2).

Connecting via network

Connect the Ethernet cable to the sensor.

Connect the other side of the Ethernet cable to the Ethernet

switch.

Connect the PC and Ethernet switch with a commercially

available network cable.

Ethernet cable

(2m/5m/10m)

Ethernet switch

For details on connecting the Ethernet cable,

refer to “Connecting the Ethernet cable” (Page 2).

The sensor and monitor do not support PoE

(Power over Ethernet). Supply power using

the power I/O cable.

Connecting the Ethernet cable

This section describes the connection method for the

Ethernet cable.

1

Align the pin connection parts of the Ethernet

cable connector with three pins of the cable

connector, and connect the cable to the sensor.

Align the pins and the pin

connection to connect

2

Tighten the connector by turning the screw-

on connector in the clockwise direction. When

connecting the connector, insert it without

inclination while pushing in and tighten it well.

(1)

Tighten the screw.

(2)

When the screw stops rotating by the locking

mechanism, further tighten it while pushing.

Repeat the steps (1) and (2) and when you cannot

tighten the screw by hand any more, use a tool such as

pliers for further tightening. Tightening torque, retorque

degree, and acceptable spaces between connectors are

shown below.

y

Ethernet cable (OP-87457/OP-87458/OP-87459)

Tightening torque

: 0.8 to 10 N·m

Retightening degree

: 5 to 10°

Spaces between connectors : 0 mm (reference value)

If the connector cable tightening is weak,

vibration may loosen the connector

and cause bad connections or cable

disconnections. Also, the enclosure

rating may not be maintained with loose

connection.

Properly follow the procedures above and

tighten the connector completely.

Advertising