KEYENCE AutoID Keyboard Wedge User Manual

Autoid keyboard wedge user's manual, Overview, Start/exit

Advertising
background image

1

E SR KBD SOFT UM

AutoID Keyboard Wedge
User's Manual

„

Symbols

The following symbols alert you to important messages. Be sure to read these
messages carefully.

Important

Provides precautions about operations that must be performed.

Point

Provides precautions on operations that can be easily mistaken.

Reference

Provides useful information or information that aids understanding of
text descriptions.

Provides reference items and pages.

1

Overview

The AutoID Keyboard Wedge is software that converts data read by a code reader
to keyboard output.

Hardware requirements

* Log in as a user that has administrator privileges.
* Use Microsoft IME or Microsoft Office IME for input.

Supported communication

• Serial communication: Communication via RS-232C or virtual COM (USB-COM).

Communicates by specifying the number of COM
connected to the code reader.

• TCP communication: Communication via Ethernet TCP.

Communicates by specifying the wait port number with
the code reader set to client and with PC set to server.

2

Start/Exit

Start-up

1

Start up the AutoID Keyboard Wedge.

The icon

is registered on the

task tray.

2

Click the [Start] button after setup.

Read this user's manual carefully prior to operating this product.
After reading, keep this manual in a safe place so that you can refer to it at any time.

OS

Windows 8 (excluding Windows RT)
Windows 7 professional (32-bit/64-bit)
Windows Vista Business/Ultimate SP2 or later (32-bit)
Windows XP SP3 or later (32-bit)

302GB

Code reader

PC

AutoID

Keyboard

Wedge

Serial communication

TCP communication

Keyboard output

Exit

1

Right-click

on the task tray.

2

Select [Exit].

* Clicking

of the AutoID Keyboard Wedge will minimize the AutoID

Keyboard Wedge.
To exit, be sure to perform exit operation from the task tray.

3

Items

This section describes the items that can be set on the AutoID Keyboard Wedge.

(1) Communication

(2) Append data

Data format

(3) Edit data

Data can be output by dividing it into multiple blocks.
This function can be used when the number of fields is set to 1 or more.

Edit data setting

*1 "Output start digit" + "Output length" = 1000 (upper limit).

[Start] button

The AutoID Keyboard Wedge starts operation with the set contents. To
launch the AutoID Keyboard Wedge at the start-up of PC, check "Run in
background at start-up".

Ethernet
communication

Check here when performing keyboard conversion of socket
communication data via Ethernet.
(Port No: 1024 to 65535)

Serial
communication

Check here when performing keyboard conversion of serial
communication data via RS-232C, etc.

Data transmission
interval

Set the time interval when inputting characters one by one.
(0 ms to 100 ms)
If keyboard conversion data is dropped, the problem may be solved by
increasing this value.

Date

Append date and time information.

Partition mark

Append partition mark. (0 to 1 character)

Header

Append characters at the beginning of data. (0 to 5 characters)

Terminator

Append characters at the end of data. (0 to 5 characters)

Header

Date

Partition mark

Read data

Terminator

Number of fields

Specify how many pieces the data is divided to.
(0 to 16)

Partition mark

Specify the partition mark of the block to output.
(Default: "," (0x2D))

No.

Specify the order of output for divided data.
(1 to 16)

Output start digit

Specify start digit for data extraction.
(1 to 999 digits)

*1

Output length

Specify the number of digits by byte to output from the output start digit.
(1 to 999 digits)

*1

Kanji conversion

If data includes Japanese such as Hiragana or Kanji, set this to "ON" to
output data by Japanese conversion.

Data replacement

This converts characters included in the data to other character strings to
output.
Maximum number of characters that can be specified as conversion
target characters is 5.

(1) Communication

(2) Append data

(3) Edit data

(4) Special key conversion

(5) Received data

Advertising