Part names and functions, System configuration figure, Connection and wiring methods – KEYENCE N-R2 User Manual

Page 2: Connecting the code reader, Connecting the power supply, Layout and wiring of the i/o terminal block, Kv -b1 6xc

Advertising
background image

2

E N-R2-IM

Connecting the code reader

Connect the code reader to the head port of the N-R2.

Pin layout of the head port

Connecting the power supply

Connect the 24 VDC power supply to the power terminal of the N-R2.

The dimensions of crimp contacts used for wiring should be as follows:

Layout and wiring of the I/O terminal block

Layout of the I/O terminal block

Wiring IN1 and IN2

Part Names and Functions

Number

Name

Function

1

Head port

Used to connect the head.

2

Power LED

Lights when the power is ON.

3

Communication status

LED

Monitors the status of communication with the
head.

4

RS-232C port

Used to connect to the host (personal
computer, PLC).

5

I/O status LED

Monitors the ON/OFF status of I/O terminals.

6

I/O terminals

Used to connect I/O signal lines of control
units.

7

Power terminal

Terminal for 24 VDC power supply input.

8

DIN rail mounting tab

A tab for mounting the DIN rail.

System Configuration Figure

Connection and Wiring Methods

Pin

number

Name

Signal name

Signal

direction

1

OUT1

OUT1 input

Input

2

OUT2

OUT2 input

Input

3

RXD

RS-232C Receive

Input

4

RTS

RS-232C Receivable

Output

5

OUT4

OUT4 input

Input

6

IN2

IN2 output

Output

7

TXD

RS-232C Transmit

Output

8

CTS

RS-232C

Transmittable

Input

9

OUT3

OUT3 input

Input

10

IN1

IN1 output

Output

11

+5V

+5V power supply

Output

8. DIN rail mounting tab

1. Head port

2. Power LED

3. Communication

status LED

4. RS-232C port

5. I/O status LED

6. I/O terminals

7. Power terminal

KV

-B1

6XC

Head port

OUT1 to 4

IN1

Head

BL Series
SR Series

Personal
computer

PLC

Timing sensor

RS-232C port

3

7

4

8

5

1

2

9

11

12

6

10

Round 12-pin jack

12

GND(SD)

Common GND

-

CAUTION

Install and remove connection cables with the power
disconnected.

CAUTION

Using a power supply other than 24 VDC may cause
product failure.

Terminal

Dimensions

Round Terminal

a: 6 mm Max.

Y terminal

a: 6 mm Max.

Item

Description

Wire size

AWG14-22

Tightening torque

0.49 N·m (4.34 lbf·in)

Wire material

Copper

Wire type

Stranded wire

Electric wire
temperature rating

+60

°C max.

Note

For connection, use stranded copper wire having a

gage of AWG16 to 26 and temperature rating of 60

°C

or higher.

The tightening torque is 0.19 N·m (1.7 lbf·in).

Power supply

24V+10%

-20%

Twist pair cable

I/O terminal
block

Circuit diagram

IN1, IN2

INCOM

Internal

circuit

Advertising