The following FDA(CDRH) label is affixed to the product.

When using this product in the countries and/or regions other than U.S.,
use the IEC warning/explanatory label in the package of this product. In
this case, it can be affixed on the FDA (CDRH) warning label, which has
already been affixed to this product.

The following safety measures are provided.
• Laser ON alarm LED (LASER ON LED)

The laser ON LED lights during radiation of laser. The LED can be
checked while wearing the safety goggles.

• laser STOP command

You can stop radiation of the laser beam furiously by issuing a
laser STOP command to the BL-700. Use the laser STOP com-
mand when it is necessary to work near the laser source, to protect
your eyes from exposure by laser beam.
When the laser is stopped by the laser STOP command, the lower-
most LED of the STABILITY LEDs lights.

CAU

TIO

N

LAS

ER RA

DIATIO

N

WH

EN O

PEN

.

DO N

OT S

TAR

E

INTO

BEA

M.

Part Names

„ BL-700

System Configuration

* Use the special setup software or exclusive setup console BL-P2E for

setting the BL series.

* As for the exclusive power supply (BL-U1, BL-U2 or N-42), refer to

the use’s manual.

No.

Name

Function

(1)

LASER ON LED

Lights while the laser is generated.

(2)

STABILITY LED

Indicates the scan stability and BL-700 operation
status.

(3)

OK/NG LED

• OK output: Green LED lights.
• NG output: Red LED lights.

(4)

TIMING LED

Lights when timing input is ON.

(5)

TEST switch

Use this switch to activate the following operations:
• Starting test mode
• Single scan of a bar code by pressing this switch

for a short time

• Use this switch to fix the communication setting to

default values.

• Clear of an error

(6)

Laser & receiver

Laser beam is sent/received through this part.

(7)

Cable

Cable length is 1.8 meters.

LASER ON

STB

OK/NG

TIMING

TEST

BL-700

(1) LASER ON LED
(2) STABILITY LED

(3) OK/NG LED

(4) TIMING LED

(5) TEST switch

(7) Cable

(6) Laser &
receiver

LASER

ON

STB

OK/NG

TIMIN

G

TEST

BL-700

BL-700

RS-232C

Serial
communication

Exclusive power supply

RS-422A

OK/NG
output

IBM PC/AT compatible

BL setting software

Timing
Input

PLC etc.

Setup console
BL-P2E

PLC (Link unit)

PLC
(RS-232C/422A unit)

PLC link

Timing sensor

Serial
communi-
cation

BL-U1, BL-U2,
N-42