KEYENCE MS2 Series User Manual

Instruction manual, Compact switching power supply, Series

Advertising
background image

1

Part Names and Functions

Safety Precautions

• Do not perform any electrical wiring while electric current is applied. Failure

to follow this may result in an electric shock or fire.

• Be sure to connect the grounding cable. Failure to follow this may result

in an electric shock or fire.

• Do not touch this unit within 1 minute after AC input is turned off. Failure

to follow this may result in an electric shock.

• Do not modify or repair this unit. Failure to follow this may result in an

electric shock, accident, or product failure.

• Do not touch any terminal of this unit while electric current is applied.

Use the unit with the terminal cover installed to avoid an electric shock.

• When this unit is used in a system that may cause a serious accident or

damage if the unit fails, be sure to install a safety device.

• Pay attention to prevent foreign matter such as metal particles, dust,

paper or wood chips from entering the inside of this unit. Failure to
follow this may result in a fire or product failure.

• Do not touch any metallic part while electric current is applied or

immediately after input is shut off. Failure to follow this may result in a
burn due to a high temperature.

• If a failure or abnormality occurs while this unit is in use, immediately

such off AC input and stop operation of this unit . Failure to follow this
may result in a fire or accident.

• Check that the AC input rated voltage of this unit is equal to the voltage

of the AC power supply.

• Do not connect the AC power supply to the DC output terminals.
• Do not disturb the convection of air near the vent of the casing.

Precautions for CE Markings

KEYENCE has evaluated the conformity of the MS2 Series with the requirements of the EMC
Directives and Low-voltage Directives under the following condition, and confirmed that the MS2
Series meets these requirements. For the Low-voltage Directives, the MS2 Series has obtained
certification from TUV Rheinland for the following standards.
<Precautions>
EMC Directives (2004/108/EC)
• Applicable standard (EMI)

EN55011, Group 1, Class A

• Applicable standard (EMS)

EN61000-6-2

Low-voltage Directives (2006/95/EC)
• Applicable standard

EN60950-1
EN50178

• Overvoltage category

II

• Pollution degree

2

• The MS2 Series is designed as a Class I Equipment. Be sure to connect the protective earthing

terminal on the terminal block to the protective earthing conductor in the building installation.

• The MS2 Series is an open-type device. Be sure to install it in an appropriate enclosure rated as

IP54 or better.

• Use the MS2 Series according to the derating conditions and the installation conditions described in

this manual.

• The MS2 Series does not include a disconnecting device. Be sure to install a disconnecting device

such as a circuit breaker in the building installation wiring.

.8.8.8

Display mode selection (MODE)
Switches the display mode.

AC input terminal (N, L)
An input cable is connected here. (100 to 240 VAC)

Protective earthing terminal (

)

Connect to the protective earthing conductor in the building
installation.

Digital display window
Displays the current values of output current/voltage and other items.

DC output terminal (+, –) *
A load is connected here. (24 VDC)

Output voltage adjustment trimmer (V.ADJ)
Adjusts the output voltage within the range of

±5%.

Compact Switching Power Supply

MS2

Series

Instruction Manual

Precautions for UL Standards

The MS2 Series meets the following UL standards and has obtained UL and C-UL certification.
• Applicable standard

UL508

Industrial Control Equipment

UL60950-1

Information Technology Equipment - Safety

CAN/CSA C22.2 No. 14-M95

Industrial Control Equipment

CAN/CSA C22.2 No. 60950-1-03

Information Technology Equipment - Safety

• UL File No.

E195940, E242533

• UL category

NMTR, NMTR7 / QQGQ2, QQGQ8

<Precautions>
• Use wires that meet the following conditions for the terminal block.

(tightening torque : 1.2 N·m)

Wire range

AWG#14-22

Wire Material

Copper wire only

Wire type

Stranded wire only

Temperature rating

60ºC/75ºC

• The MS2 Series is designed as a Class I Equipment. Be sure to connect the protective earthing

terminal on the terminal block to the protective earthing conductor in the building installation.

• The MS2 Series is an open-type device. Be sure to install it in an appropriate enclosure rated as

IP54 or better.

• Use the MS2 Series according to the derating conditions and the installation conditions described in

this manual.

• The MS2 Series does not include a disconnecting device. Be sure to install a disconnecting device

such as a circuit breaker in the building installation wiring.

• The output of the MS2-H50 is rated Class 2 output specified in NFPA70 (NEC: National

Electrical

Code) in the U.S.A. (UL Category: EPBU2/EPBU8)

Installation Conditions

Installation environment

• Installation this unit indoors.
• Do not install this unit in locations exposed to direct sunlight.
• Do not install this unit in locations in which there is corrosive gas or flammable gas.
• Do not install this unit in locations exposed to a lot of dust, soot, or steam.
• Do not install this unit in locations in which water, oil, or chemicals may splash onto the unit.
• When installing this unit in a location subject to vibration or impact, consider the vibration proof

mounting.

When installing this unit in a control console

• The ambient temperature for this unit should not exceed the upper temperature limit (refer to the

derating characteristic). When the upper temperature limit may be exceeded, install a cooling fan or
cooler so that the ambient temperature is below the upper temperature limit.

• Leave a sufficient ventilation space around this unit for head dissipation.
• Do not install this unit just above a device with high head generation (transformer, inverter, servo

amplifier, etc.).

Installation

Space around the unit

The MS2 Series uses natural air-cooling. To ensure sufficient convection of air to dissipate heat, provide
enough space between the MS2 Series and the control panel or other nearby devices as shown below.

Installation orientation

Install this unit with the base A down as shown below. Do not install the unit in any other orientation.

Mounting bracket (optional)

Make sure that the tightening torque for the mounting screw holes of this unit is 0.5 N•m or less.

Wiring

Terminals

Screw size

Tightening torque

M4

1.2 N•m

Crimp termianls

Cables

Select cables with a wire diameter suited to the output rated current.

8.0 mm max.

8.0 mm max.

M4 size

M4 size

20mm min.

20mm min.

20mm min.

20mm min.

Danger

Warning

Caution

*Only the MS2-H300 has DC output of 4-terminal.

MS2-H50/H75/H100/H150

60mm min.

30mm min.

30mm min.

30mm

min.

MS2-H300