CHAPTER 8 – CORRECTIVE MAINTENANCE

Page 74 of 138

AERCO International, Inc.

 100 Oritani Dr.  Blauvelt, NY 10913

OMM-0069_0E

PRI: 11/26/2013

Phone: 800-526-0288

SP-100

4. When the plates of the Heat Exchanger are assembled and tightened, the gasket provides

a tight seal around the plate.

5. Before closing the plate pack, check to ensure that the gasket prongs are in the correct

position.

8.8.2 Replacing Gaskets on End Plate (First Plate Against Frame Plate)

1. Obtain two standard plate gaskets (Part No. 81128).

2. Cut the gaskets as indicated in Figure 8-15.

3. Attach gasket to plate as indicated in Figure 8-16.


Figure 8-15. Cutting Gaskets For End Plate