5. Pull straight up to unplug the Module from the Valve Head.

6. Install the replacement Electronics Module on the Valve Head and resecure it with the

three socket head screws removed in step 4.

7. Refer to Figure 8-7 and ensure that the three (3) DIP switches on the replacement Module

are all in the OFF (down) position.

8. Reconnect the power and control signal wire leads to the Electronics Module.

9. Turn ON the POWER Switch on the side of the ECS/SP Control Box.

10. Recalibrate the Control Valve using the procedures in Chapter 3, paragraph 4.2.1.

11. Replace the cover on the Electronics Module after the Valve has been successfully

calibrated.

12. Return the SmartPlate Water Heater to service.