(3) Flow Direction

Install the delector in accordance with the flow direction arrow on the detector. See I’ignre 4,5.

If the actual flow runs opposite to the specified flow direction, the following display and

output appears.. (For bidirectional multi-range measurement, sec 103^ “Mulli-rangc

Functions/’).

* LCD display (optional)« Instantaneous How rate—indicates negative values»

Totalized flow—no a>unts added,

* Output:Current output—4.0 mA output; Pulse output—No pulses

For bidirectional range measuremenu the flow in opposite direction results in a positive

output value. See 10.3» “Multi-range Functions/’

(4) Preventing sin Empty Pipe Condition

Design an upright pipe run (Figure 4.6) or sufficicjit head pressure (Fig, 4.7) at the

downstream detector oullet if there is a possibility of the detector pipe becoming emptied.

Upright pipe run

Figure 4«6 Detector with 3n upright pipe run at dow'ustream outlet

Detector

Z

Figure 4.7 Detector with sufficient head pressure at downstream outlet