Pnod pr55 panel operation permission, Cr.ufc panel operation permission, U r . u " b – Toshiba Tosvert VF-A5 User Manual
Page 90: Panel operation permission
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

u r . u
" b
(Utility Parameters)
P n O d P R 5 5
Panel operation permission
Related parameters
P n O d Panel operation mode selection
P R 5 5
Pass number
Various levels of key operations can be prohibited to prevent accidental or unwanted operations.
P n D d
setting value
Function
D
Prohibit all key operations
+ I
Can perform reset
+
3
Can perform monitor operations
+ H
Can perform emergency stop
+
B
Can perform run/stop operations
+ I E
Can perform parameter read operations
+ 3 3
Can perform parameter change operations
B 3
Standard mode (all operations possible)
* Data setting of parameters indicated as using the ■+' mark is performed as follows:
Example) Set (+ /) +
i+S)
- 3 and both + | and + E become valid.
Canceling the "prohibit all key operations" mode
1. Simultaneously press the following four keys.
PANEUREMOTE
A
PRG
ENTER
After these keys have been pressed, D will be displayed on the LED display.
2. Input the pass number by selecting it with the
A V
keys. (Note)
3.
Press ENTER
This will cancel the ‘prohibit all key operations* mode.
(Note) The pass number can be set between 0 and 99 with the
P R 5 5
parameter. Set this number
before setting P f l D d • The default value is D.
The
I P R O d
setting is validated after power has been cycled OFF and ON or after a fault reset and
subsequent system initialization.
* If ‘can perform parameter change operations* is selected, ‘can perform parameter read operations* must also
be selected in order to access and change parameter settings.
84