Panel operation permission

Related parameters

P n O d Panel operation mode selection

P R 5 5

Pass number

Various levels of key operations can be prohibited to prevent accidental or unwanted operations.

P n D d

setting value

Function

D

Prohibit all key operations

+ I

Can perform reset

+

3

Can perform monitor operations

+ H

Can perform emergency stop

+

B

Can perform run/stop operations

+ I E

Can perform parameter read operations

+ 3 3

Can perform parameter change operations

B 3

Standard mode (all operations possible)

* Data setting of parameters indicated as using the ■+' mark is performed as follows:

Example) Set (+ /) +

i+S)

- 3 and both + | and + E become valid.

Canceling the "prohibit all key operations" mode

1. Simultaneously press the following four keys.

PANEUREMOTE

A

PRG

ENTER

After these keys have been pressed, D will be displayed on the LED display.

2. Input the pass number by selecting it with the

A V

keys. (Note)

3.

Press ENTER

This will cancel the ‘prohibit all key operations* mode.

(Note) The pass number can be set between 0 and 99 with the

P R 5 5

parameter. Set this number

before setting P f l D d • The default value is D.

The

I P R O d

setting is validated after power has been cycled OFF and ON or after a fault reset and

subsequent system initialization.

* If ‘can perform parameter change operations* is selected, ‘can perform parameter read operations* must also

be selected in order to access and change parameter settings.