This setting must be done when F/F mixing is
used.

(19) Pitch low setting

default: 1940 uS

This sets the minimum pitch point of GY701.
Move the pitch stick to minimum pitch, push
data+ or – key. The minimum pitch signal is
memorized in the GY701. The display shows
mark at the setting point. This setting must be
done when F/F mixing is used.

(20) Pitch high setting

default: 1100 uS

This sets the maximum pitch point of GY701.
Move the pitch stick to maximum pitch, push
data+ or – key. The maximum pitch signal is
memorized in the GY701. The display shows
mark at the setting point. This setting must be
done when F/F mixing is used.

(21) Sensor mode

default: Middle

It selects the response of the gyro sensor signal.
The response is set as Moderate→Middle→Quick,
but the stability is vice versa. Select the good
match for the individual heli. Pushing data+ or –

Advertising