6) throttle data mode, 7) revolution change up delay – Futaba GY701 User Manual

Page 76

Advertising
background image

G

OVERNOR

E

XPERT

S

ETTING

76

(6) Throttle data mode

default: Optimize

This selects the throttle input operation. Pushing
data+ or – key, the mode is changed

Optimize:

GY701 sets the throttle input signal to optimum.
No need to consider the throttle curve setting on the
transmitter.

Fixed:

The fixed throttle input is utilized related to the revo-
lution. It is recommended for electric motors.

Tx.Curve:

GY701 uses the exact throttle input from the trans-
mitter. The throttle curve setting on the transmitter
is required. When the Rev.Lmt mode is selected, this
mode should be selected.

(7) Revolution change up delay

default:

8

range:

2

20

This sets the delay of the revolution from low
to high. Pushing data+ or – key, the value is
changed.

(8) Revolution down delay

default:

10

range:

2

20

Advertising