GTCO Summagrid IV - Users Guide Part 2 User Manual

Page 15

Advertising
background image

Summagrid IV 15

1.16 Resolution Commands: Variable Resolution

1.16.1 Description

The Variable Resolution command is used to define the resolution of each axis
independently. It allows the user to set the resolution to any whole number from
0001 to 2540.

1.16.2 When to Use

Variable Resolution is used to match the tablet resolution to that of a graphics
terminal. The resolution of a graphics terminal is measured in pixels, a unit of
measurement similar to counts. Therefore, to match the measurement system of
the graphics terminal (pixels) to that of the tablet (inches), the Summagrid IV
automatically changes the report format of the tablet to counts.

1.16.3 Command Syntax

Variable Resolution

<ESC>P[a][bbbb]

X Axis

Y Axis

a=X
bbbb=ASCII value from 0001 to 2540 lpi

a=Y
bbbb=ASCII value from 0001 to 2540 lpi

1.17 Resolution Commands: Confirm Resolution

1.17.1 Description

The Confirm Resolution command is used to send a report to the host that specifies
the maximum X and Y values at the current resolution setting. When the user sends
a Confirm Resolution command, the tablet dimensions are multiplied by the
resolution and the results are sent to the host in the data format previously
selected.

1.17.2 When to Use

Use this command to verify a Variable Resolution setting.

1.17.3 Command Syntax

Confirm Resolution

<ESC>a

Advertising