Check Method of Causes

Repair Method

Explanation Figures

EC-1200 EC-1600 EC-3600 EC-3700

Applicable Models:

Cateye Ergociser Series 1000 Service Manual

11

T-1

T-1

Black Cable

No Display on Control Unit after Power ON. (1)

Check the power is available at the wall socket before proceeding to

checking of causes.

[1] Checking the AC Adapter

1. Detach the plug of AC adapter from the AC adapter inlet of the

main unit.

2. Connect the wall socket plug of the AC adapter to the wall

socket.

3. Using a tester, measure the voltage at the plug which will be

connected to the main unit. (Fig. 1)

The AC adapter will be working fine, if the voltage is minus

(-) at the inner area and plus (+) at the outer area of the

connector and also the meter reading is in the range of 14V

and 19V.

When the measured voltage is 0V, or less than 14V, the

AC adapter will be defective.

Note: Never short-circuit the plug of AC adapter. This will

damage the AC adapter.

[2] Checking the Wiring within the Frame

1. When the AC adapter is found to be correct, proceed to

checking of wiring within the frame. Loosen the four screws

on the handlebar stem to remove the control unit. (Fig. 2)

2. Remove the 5P cable which is connected to the back of the

control unit. (Fig. 2)

3. Connect the AC adapter, and turn on the main unit.

4. Using a tester, measure the voltage across the terminals 1 (-)

and 3 (+) of the 5P cable. (Fig. 3)

The main unit side will be working fine if the meter reading

is in the range of 14V and 19V. This means the control unit

will be defective.

Fig. 1

Normal for 14V thru 19V

Red Cable

DC Connector

Fig. 2

Cable Connector

Fig. 3

Normal for 14V thru 19V

Black Cable

Red Cable

5P Cable

Terminal 1 (-)

No Display on Control Unit after Power ON. (1)

Replace the AC adapter.

Replace the control unit.

Terminal
3 (+)