Es-6, Replacing the panel keyboard – CatEye EC-3600 User Manual

Page 32

Advertising
background image

Cateye Ergociser Series 1000 Service Manual
30

EC-1200 EC-1600 EC-3600 EC-3700

Applicable Models:

ES-6

ES-6

Fig. 1

Control Unit

Cable Connector

Fig. 2

Screw

Control Unit

Fig. 3

Substrate

Substrate
Fixing Screw

Connector

Fig. 4

Silicon

Fig. 5

Control Unit

Upper Body

Panel Keyboard

Fig. 6

Silicon

Replacing the Panel Keyboard

1. Remove the control unit by loosening four screws. Also

remove the cable connector from the control unit. (Fig. 1)

2. The control unit can be separated into upper and lower parts

when the eight screws on the bottom of the lower body of the

unit are removed (Fig. 2). Be careful to separate them slowly

since the upper and lower bodies are connected with a flat

cable.

3. Remove the connector on the panel keyboard which is located

at the upper body side, loosen the nine screws on the

substrate, and remove them from the upper body. (Fig. 3)

4. Since the panel keyboard is fixed to the control unit with

silicon, cut the silicon with a sharp cutter (Fig. 4). Peel the

panel keyboard off the surface of upper body. (Fig. 5)

5. If the silicon remains at the upper body, remove it thoroughly.

6. Place the brandnew panel keyboard. The cable from the

keyboard should be pulled in through the hole on the upper

body. Press and adhere the panel keyboard in position.

7. Apply silicon at two depicted areas to prevent intrusion of

sweat. (Figs. 4 and 6)

8. Mount the substrate and fix it with nine screws, and insert the

connector of the panel keyboard. (Fig. 3)

9. Put the upper and lower body together, and fix them with eight

screws.

10. Connect the cable connector to the control unit, and mount the

unit to the main unit.

Replacing the Panel Keyboard

Advertising